The most frequently used method in a three dimensional human gait analysis involves placing markers on the skin of the analyzed segment. This introduces a significant artifact, which strongly influences the bone position and orientation and joint kinematic estimates. In this study, we tested and evaluated the effect of adding a Kalman filter procedure to the previously reported point cluster technique (PCT) in the estimation of a rigid body motion. We demonstrated the procedures by motion analysis of a compound planar pendulum from indirect opto-electronic measurements of markers attached to an elastic appendage that is restrained to slide along the rigid body long axis. The elastic frequency is close to the pendulum frequency, as in the biomechanical problem, where the soft tissue frequency content is similar to the actual movement of the bones. Comparison of the real pendulum angle to that obtained by several estimation procedures—PCT, Kalman filter followed by PCT, and low pass filter followed by PCT—enables evaluation of the accuracy of the procedures. When comparing the maximal amplitude, no effect was noted by adding the Kalman filter; however, a closer look at the signal revealed that the estimated angle based only on the PCT method was very noisy with fluctuation, while the estimated angle based on the Kalman filter followed by the PCT was a smooth signal. It was also noted that the instantaneous frequencies obtained from the estimated angle based on the PCT method is more dispersed than those obtained from the estimated angle based on Kalman filter followed by the PCT method. Addition of a Kalman filter to the PCT method in the estimation procedure of rigid body motion results in a smoother signal that better represents the real motion, with less signal distortion than when using a digital low pass filter. Furthermore, it can be concluded that adding a Kalman filter to the PCT procedure substantially reduces the dispersion of the maximal and minimal instantaneous frequencies.

1.
Chan
,
M.
, 1993,
Evaluation of the Use of Knee Braces Based on the Intrinsic Kinematics of a Normal Knee
,
MIT
,
Cambridge, MA
.
2.
Lafortune
,
M. A.
,
Cavanaugh
,
P. R.
,
Sommer
,
H. J.
, and
Kalenak
,
A.
, 1992, “
Three-Dimensional Kinematics of the Human Knee During Walking
,”
J. Biomech.
0021-9290,
25
, pp.
347
357
.
3.
Murphy
,
M. C.
, and
Mann
,
R. W.
, 1991, “
Estimation of the Instantaneous Kinematics of the Normal Human Knee In Vivo
,”
37th Annual Meeting of the Orthopaedic Research Society
, Anaheim, CA.
4.
Andriacchi
,
T. P.
,
Alexander
,
E. J.
,
Toney
,
M. K.
,
Dyrby
,
C.
, and
Sum
,
J.
, 1998, “
A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics
,”
ASME J. Biomech. Eng.
0148-0731,
120
, pp.
743
749
.
5.
Manal
,
K.
,
McClay
,
I.
,
Galinat
,
B.
, and
Stanhope
,
S.
, 2003, “
The Accuracy of Estimating Proximal Tibial Translation During Natural Cadence Walking: One vs. Skin Mounted Targets
,”
Clin. Biomech. (Bristol, Avon)
0268-0033,
18
, pp.
126
131
.
6.
Cappello
,
A.
,
Stagni
,
R.
,
Fantozzi
,
S.
, and
Leardini
,
A.
, 2005, “
Soft Tissue Artifact Compensation in Knee Kinematics by Double Anatomical Landmark Calibration: Performance of a Novel Method During Selected Motor Tasks
,”
IEEE Trans. Biomed. Eng.
0018-9294,
52
(
6
), pp.
992
998
.
7.
Cerveri
,
P.
,
Rabuffetti
,
M.
,
Pedotti
,
V.
, and
Ferrigno
,
G.
, 2003, “
Real-Time Human Motion Estimation Using Biomechanical Models and Non-Linear State-Space Filters
,”
Med. Biol. Eng. Comput.
0140-0118,
41
, pp.
109
123
.
8.
Reinschmidt
,
C.
,
Van Den Bogert
,
A. J.
,
Lundberg
,
A.
,
Nigg
,
B. M.
, and
Murphy
,
N.
, 1997, “
Effect of Skin Movement on the Analysis of Skeletal Knee Joint Motion During Running
,”
J. Biomech.
0021-9290,
30
(
7
), pp.
729
732
.
9.
Ryu
,
J. H.
,
Kouchi
,
M.
,
Mochimaru
,
M.
, and
Lee
,
K. H.
, 2003, “
Analysis of Skin Movements With Respect to Bone Motions Using MR Images
,”
International Journal of CAD/CAM
,
3
(
2
), pp.
61
66
.
10.
Chèze
,
L.
,
Fregly
,
B. J.
, and
Dimnet
,
J.
, 1995, “
A Solidification Procedure to Facilitate Kinematic Analysis Based on Video System Data
,”
J. Biomech.
0021-9290,
28
, pp.
879
884
.
11.
Leardini
,
A.
,
Chiari
,
L.
,
Croce
,
U. D.
, and
Cappozzo
,
A.
, 2005, “
Human Movement Analysis Using Stereophotogrammetry—Part 3: Soft Tissue Artifact Assessment and Compensation
,”
Gait and Posture
0966-6362,
21
, pp.
212
225
.
12.
Vithani
,
A. R.
, and
Gupta
,
K. C.
, 2004, “
Estimation of Object Kinematics From Point Data
,”
J. Mech. Des.
1050-0472,
126
, pp.
16
21
.
13.
Lu
,
T. -W.
, and
O'Connor
,
J. J.
, 1999, “
Bone Position Estimation From Skin Marker Co-Ordinates Using Global Optimisation With Joint Constraints
,”
J. Biomech.
0021-9290,
32
, pp.
129
134
.
14.
Cerveri
,
P.
,
Pedotti
,
A.
, and
Ferrigno
,
G.
, 2004, “
Non-Invasive Approach Towards the In Vivo Estimation of 3D Inter-Vertebral Movements: Methods and Preliminary Results
,”
Med. Eng. Phys.
1350-4533,
26
, pp.
841
853
.
15.
Choset
,
H.
,
Lynch
,
K. M.
,
Hutchinson
,
S.
,
Kantor
,
G.
,
Burgard
,
W.
,
Kavraki
,
L. E.
, and
Thrun
,
S.
, 2005, “
Kalman Filtering
,”
Principles of Robot Motion: Theory, Algorithms, and Implementation
,
Massachusetts Institute of Technology
,
Cambridge, MA
, pp.
269
301
.
16.
Fioretti
,
S.
, and
Jetto
,
L.
, 1989, “
Accurate Derivative Estimation From Noisy Data: A State-Space Approach
,”
Int. J. Syst. Sci.
0020-7721,
20
(
1
), pp.
33
53
.
17.
David
,
A. W.
, 1930,
Biomechanics and Motor Control of Human Movement
,
Wiley
,
New York
, pp.
33
45
.
18.
Vicon Motion Systems and Peak Performance Inc.
, 2007, http://www.vicon.comhttp://www.vicon.com.