Skip Nav Destination
Issues
October 2017
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
Vaginal Changes Due to Varying Degrees of Rectocele Prolapse: A Computational Study
Arnab Chanda, Isuzu Meyer, Holly E. Richter, Mark E. Lockhart, Fabia R. D. Moraes, Vinu Unnikrishnan
J Biomech Eng. October 2017, 139(10): 101001.
doi: https://doi.org/10.1115/1.4037222
Topics:
Canals
,
Magnetic resonance imaging
,
Stress
,
Biological tissues
,
Muscle
,
Finite element analysis
,
Modeling
,
Displacement
,
Anatomy
,
Pressure
The Role of Neck Muscle Activities on the Risk of Mild Traumatic Brain Injury in American Football
J Biomech Eng. October 2017, 139(10): 101002.
doi: https://doi.org/10.1115/1.4037399
Topics:
Muscle
,
Risk
,
Traumatic brain injury
,
Wounds
Experimental Study of Anisotropic Stress/Strain Relationships of Aortic and Pulmonary Artery Homografts and Synthetic Vascular Grafts
Yueqian Jia, Yangyang Qiao, I. Ricardo Argueta-Morales, Aung Maung, Jack Norfleet, Yuanli Bai, Eduardo Divo, Alain J. Kassab, William M. DeCampli
J Biomech Eng. October 2017, 139(10): 101003.
doi: https://doi.org/10.1115/1.4037400
Topics:
Anisotropy
,
Biological tissues
,
Mechanical properties
,
Pulmonary artery
,
Stiffness
,
Stress
,
Stress-strain relations
,
Vessels
,
Biomechanics
,
Aorta
Effects of Lumbar Spine Assemblies and Body-Borne Equipment Mass on Anthropomorphic Test Device Responses During Drop Tests
J Biomech Eng. October 2017, 139(10): 101004.
doi: https://doi.org/10.1115/1.4037401
Topics:
Lumbar spine
,
Stress
Variable Thumb Moment Arm Modeling and Thumb-Tip Force Production of a Human-Like Robotic Hand
J Biomech Eng. October 2017, 139(10): 101005.
doi: https://doi.org/10.1115/1.4037402
Modal Damping Ratio and Optimal Elastic Moduli of Human Body Segments for Anthropometric Vibratory Model of Standing Subjects
J Biomech Eng. October 2017, 139(10): 101006.
doi: https://doi.org/10.1115/1.4037403
Topics:
Damping
,
Elastic moduli
,
Excitation
,
Stiffness
Strain-Level Dependent Nonequilibrium Anisotropic Viscoelasticity: Application to the Abdominal Muscle
J Biomech Eng. October 2017, 139(10): 101007.
doi: https://doi.org/10.1115/1.4037405
Topics:
Anisotropy
,
Deformation
,
Relaxation (Physics)
,
Stress
,
Viscoelasticity
,
Viscosity
,
Muscle
,
Biological tissues
Endogenous Sheet-Averaged Tension Within a Large Epithelial Cell Colony
J Biomech Eng. October 2017, 139(10): 101008.
doi: https://doi.org/10.1115/1.4037404
Simulation Analysis of Linear Quadratic Regulator Control of Sagittal-Plane Human Walking—Implications for Exoskeletons
J Biomech Eng. October 2017, 139(10): 101009.
doi: https://doi.org/10.1115/1.4037560
Topics:
Control equipment
,
Dynamics (Mechanics)
,
Exoskeleton devices
,
Feedback
,
Torque
,
Errors
,
Kinematics
Finite Element Biomechanics of Optic Nerve Sheath Traction in Adduction
J Biomech Eng. October 2017, 139(10): 101010.
doi: https://doi.org/10.1115/1.4037562
Topics:
Biological tissues
,
Biomechanics
,
Finite element analysis
,
Simulation
,
Stress
,
Traction
,
Elastic moduli
Technical Brief
Repeatability of a Dislocation Spinal Cord Injury Model in a Rat—A High-Speed Biomechanical Analysis
J Biomech Eng. October 2017, 139(10): 104501.
doi: https://doi.org/10.1115/1.4037224
Topics:
Biomechanics
,
Clamps (Tools)
,
Dislocations
,
Spinal cord
,
Wounds
,
X-rays
,
Kinematics
,
Design
,
Rotation
Reporting the Fatigue Life of 316L Stainless Steel Locking Compression Plate Implants: The Role of the Femoral and Tibial Biomechanics During the Gait
J Biomech Eng. October 2017, 139(10): 104502.
doi: https://doi.org/10.1115/1.4037561
Topics:
Biomechanics
,
Fatigue life
,
Knee
,
Stainless steel
,
Cycles
,
Bone fractures
,
Weight (Mass)
,
Fatigue analysis
,
Compression
,
Fatigue
Biaxial Mechanical Assessment of the Murine Vaginal Wall Using Extension–Inflation Testing
J Biomech Eng. October 2017, 139(10): 104504.
doi: https://doi.org/10.1115/1.4037559
Topics:
Anisotropy
,
Cycles
,
Pressure
,
Pseudoelasticity
,
Stress
,
Testing
,
Biological tissues
,
Biomechanics
,
Mechanical behavior
,
Physiology
Technical Brief
Influence of Scan Resolution, Thresholding, and Reconstruction Algorithm on Computed Tomography-Based Kinematic Measurements
J Biomech Eng. October 2017, 139(10): 104503.
doi: https://doi.org/10.1115/1.4037558
Topics:
Algorithms
,
Bone
,
Kinematics
,
Resolution (Optics)
,
Errors
,
Image segmentation
,
Bricks
Email alerts
RSS Feeds
Effect of Blade Thickness on Hemodynamics and Hemolysis: A Case Study of Pediatric Centrifugal Blood Pumps
J Biomech Eng (February 2025)
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)