Abstract
A microprocessor-controlled, automated extraction/concentration device, the Prep 1 (Du Pont Clinical Systems), was evaluated for application to the isolation of drug substances from postmortem fluids and tissue homogenates. Two classes of materials were investigated: barbiturates and the benzodiazepine, diazepam. With as little as 200 mg of tissue, barbiturate derivatives were successfully isolated and measured by gas chromatography using nitrogen-phosphorus detection with a coefficient of variation of 2 to 5%. Diazepam was measured in a similar fashion with a coefficient of variation of 4.4%. Preliminary investigation indicates that this system is applicable to a wide range of drug substances of toxicological interest.
Issue Section:
Research Papers
References
1.
Williams
, R. C.
and Viola
, J. L.
, “Application of an Automated Extractor/Concentrator to the Analysis of Anticonvulsant Drugs in Blood Serum by High Performance Liquid Chromatography
,” Journal of Chromatography
, Vol. 185
, 20
12
1979
, pp. 505
–513
.2.
St. Onge
, L.
, Dolar
, E.
, Anglim
, M. A.
, and Least
, C. J.
, “Improved Determination of Phenobarbital, Primidone, and Phenytoin by Use of a Preparative Instrument for Extraction, Followed by Gas Chromatography
,” Clinical Chemistry
, Vol. 25
, No. 8
, 08
1979
, pp. 1373
–1376
.3.
Williams
, R. C.
, “Application of an Automated Sample Processor to the Analysis of Benzodiazepine Drugs and Their Metabolites in Blood Serum by HPLC
,” Fresenius Zeitschrift für Analytische Chemie
, Vol. 301
, 1980
, pp. 116
–117
.4.
Fujimoto
, J. M.
and Wang
, R. I.
, “A Method of Identifying Narcotic Analgesics in Human Urine After Therapeutic Doses
,” Toxicology and Applied Pharmacology
0041-008X. Vol. 16
, 1970
, pp. 186
–189
.5.
Weissman
, N.
, Lowe
, M. L.
, Beattle
, J. M.
, and Demetrios
, J. A.
, “Screening Method for Detection of Drugs of Abuse in Human Urine
,” Clinical Chemistry
, Vol. 17
, 1971
, pp. 875
–881
.6.
Pranitis
, P. A. F.
, Milzoff
, J. R.
, and Stolman
, A.
, “Extraction of Drugs from Biofluids and Tissues with XAD-2 Resin
,” Journal of Forensic Sciences
, Vol. 19
, No. 4
, 10
1974
, pp. 917
–926
.7.
Mulé
, S. I.
, Bastos
, M. L.
, Jukofsky
, D.
, and Saffer
, E.
, “Routine Identification of Drugs of Abuse in Human Urine: II, Development and Application of the XAD-2 Resin Column Method
,” Journal of Chromatography
, Vol. 63
, 23
12
1971
, pp. 289
–301
.8.
Bastos
, M. L.
, Jukofsky
, D.
, Saffer
, E.
, Chedikel
, M.
, and Mul$#x00E9;
, S. J.
, “Modifications of the XAD-2 Resin Column Method for the Extraction of Drugs of Abuse from Human Urine
,” Journal of Chromatography
, Vol. 72
, 20
09
1972
, pp. 549
–553
.9.
Bastos
, M. L.
, Jukofsky
, D.
, and Mul$#X00E9;
, S. J.
, “Routine Identification of Drugs of Abuse in Human Urine: III. Differential Elution of the XAD-2 Resin
,” Journal of Chromatography
, Vol. 81
, 27
06
1973
, pp. 93
–98
.10.
Kullberg
, M. P.
, Miller
, W. L.
, McGowen
, F. J.
, and Doctor
, B. P.
, “Studies on the Single Extraction of Amphetamine and Phenobarbital from Urine Using XAD-2 Resin
,” Biochemical Medicine
, Vol. 7
, 04
1973
, pp. 328
–335
.11.
Kullberg
, M. P.
and Gorodetsky
, C. W.
, “Studies on the Use of XAD-2 Resin for Detection of Abused Drugs in Urine
,” Clinical Chemistry
, Vol. 20
, 02
1974
, pp. 177
–183
.12.
Miller
, W. L.
, Kullberg
, M. P.
, Barning
, M. E.
, Brown
, L. D.
, and Doctor
, B. P.
, “Studies on the Quantitative Extraction of Morphine from Urine Using Nonionic XAD-2 Resin
,” Biochemical Medicine
. Vol. 7
, 02
1973
, pp. 145
–158
.13.
Caplan
, Y. H.
, Backer
, R. C.
, Staji$#X00E9;
, M.
, and Thompson
, B. C.
, “Detection of Drugs Using XAD-2 Resin. III: A Routine Screening Procedure for Bile
,” Journal of Forensic Sciences
, Vol. 24
, No. 4
, 10
1979
, pp. 745
–751
.14.
Stajié
, M.
, Caplan
, Y. H.
, and Backer
R. C.
, “Detection of Drugs Using XAD-2 Resin. II: Analysis of Liver in Medical Examiner's Cases
,” Journal of Forensic Sciences
, Vol. 24
, No. 4
, 10
1979
, pp. 732
–744
.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.
You do not currently have access to this content.