Abstract
Fuller and Griffiths first demonstrated the feasibility of obtaining an infrared spectrum directly on an intact Empirin® tablet using diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). We have found that several modifications of this method are necessary to obtain useful spectra for most other tablets. Applications of these modified procedures to the analysis of several tablets of forensic science interest are presented, and the results are compared to those obtained by conventional means. The direct analysis of some capsule contents and other powders is also presented and discussed.
Issue Section:
Research Papers
References
1.
Fuller
, M. P.
and Griffiths
, P. R.
, “Infrared Analysis by Diffuse Reflectance Spectrometry
,” American Laboratory
, Vol. 72
, 10
1978
, pp. 69
-80
.2.
Griffiths
, P. R.
, Kuehl
, D.
, and Fuller
, M. P.
, “Applications of Fourier Transform Infrared Spectrometry in Forensic Analysis
,” in Proceedings of the International Symposium on Instrumental Applications in Forensic Drug Chemistry
, U.S. Government Printing Office
, Washington, DC
, 05
1978
.3.
Suzuki
, E. M.
and Gresham
, W. R.
, “Forensic Science Applications of Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS): I. Principles, Sampling Methods, and Advantages
,” Journal of Forensic Sciences
0022-1198, Vol. 31
, No. 3
, 07
1986
, pp. 931
-952
.4.
Yeboah
, S. A.
, Wang
, S.
, and Griffiths
, P. R.
, “Effect of Pressure on Diffuse Reflectance Infrared Spectra of Compressed Powders
,” Applied Spectroscopy
0003-7028, Vol. 38
, No. 2
, 1984
, pp. 259
-264
.5.
Fuller
, M. P.
and Griffiths
, P. R.
, “Diffuse Reflectance Measurements by Infrared Fourier Transform Spectroscopy
,” Analytical Chemistry
0003-2700 https://doi.org/10.1021/ac50035a045, Vol. 50
, No. 13
, 11
1978
, pp. 1906
-1910
.6.
Vincent
, R. K.
and Hunt
, G. R.
, “Infrared Reflectance from Mat Surfaces
,” Applied Optics
0003-6935, Vol. 7
, No. 1
, 01
1968
, pp. 53
-59
.7.
Griffiths
, P. R.
and Fuller
, M. P.
, “Mid-Infrared Spectrometry of Powdered Samples
,” in Advances in Infrared and Raman Spectroscopy
, Vol. 9
, Heyden and Sons, Ltd.
, Philadelphia
, 1982
, pp. 63
-129
.8.
Kubelka
, P.
and Munk
, F.
, in Zeitschrift für Technische Physik
, Vol. 12
, 1931
, p. 593.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.