Abstract

With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism® 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of ± 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised ≥5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType™ PM + DQA1, and/or D1S80) were amplified using AmpFℓSTR® Profiler Plus™ and COfiler™ and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects or victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.

References

1.
Budowle
B
,
Moretti
T R
.
Forensics: analysis of short tandem repeat loci by multiplex PCR and real-time fluorescence detection during capillary electrophoresis
. In:
Epplen
J T
,
Lubjuhn
T
, editors.
Methods and tools in biosciences and medicine: DNA profiling and DNA fingerprinting
.
Basel, Switzerland
,
Birkhäuser Verlag
,
1999
;
101
-
15
.
2.
Ulfelder
K J
,
Schwartz
H E
,
Hall
J M
,
Sunzeri
F J
.
Restriction fragment length polymorphism analysis of ERBB2 oncogene by capillary electrophoresis
.
Anal Biochem
1992
;
200
:
260
-
7
.
3.
Landers
J P
,
Oda
R P
,
Spelsberg
T C
,
Nolan
J A
,
Ulfelder
K J
.
Capillary electrophoresis: a powerful micro-analytical technique for biologicallyactive molecules
.
Bio Techniques
1993
;
14
:
98
-
111
.
4.
McCord
B R
,
Jung
J M
,
Holleran
E A
.
High resolution capillary electrophoresis of forensic DNA using a non-gel sieving buffer
.
J Liq Chromatogr
1993
;
16
:
1963
-
81
.
5.
Buel
E
,
Schwartz
M B
,
LaFountain
M J
.
Capillary electrophoresis STR analysis: comparison to gel-based systems
.
J Forensic Sci
1998
;
43
:
164
-
70
.
6.
Lazaruk
K
,
Walsh
P S
,
Oaks
F
,
Gilbert
D
,
Rosenblum
B B
,
Menchen
S
, et al
Genotyping of forensic short tandem repeat (STR) systems based on sizing precision in a capillary electrophoresis instrument
.
Electrophoresis
 0173-0835
1998
;
86
-
93
.
7.
Isenberg
A R
,
McCord
B R
,
Koons
B W
,
Budowle
B
,
Allen
R O
.
DNA typing of a polymerase chain reaction amplified D1S80/amelogenin multiplex using capillary electrophoresis and a mixed entangled polymer matrix
.
Electrophoresis
 0173-0835
1996
;
17
:
1505
-
11
.
8.
Butler
J M
,
McCord
B R
,
Jung
J M
,
Lee
J A
,
Budowle
B
,
Allen
R O
.
Application of dual internal standards for precise sizing of polymerase chain reaction products using capillary electrophoresis
.
Electrophoresis
 0173-0835
1995
;
16
:
974
-
80
.
9.
Butler
J M
,
McCord
B R
,
Jung
J M
,
Allen
R O
.
Rapid analysis of the short tandem repeat HUMTH01 by capillary electrophoresis
.
Bio Techniques
1994
;
17
:
1062
-
4
.
10.
Ruiz-Martinez
M C
,
Berka
J
,
Belenkii
A
,
Foret
F
,
Miller
A W
,
Karger
B L
.
DNA sequencing by capillary electrophoresis with replaceable linear polyacrylamide and laser-induced fluorescence detection
.
Anal Chem
1993
;
65
:
2851
-
8
.
11.
Zagursky
R J
,
McCormick
R M
.
DNA sequencing separations in capillary gels on a modified commercial DNA sequencing instrument
.
Bio Techniques
1990
;
9
:
74
-
9
.
12.
Drossman
H
,
Luckey
J A
,
Kostichka
A J
,
D'Cunha
J
,
Smith
L M
.
Highspeed separations of DNA sequencing reactions by capillary electrophoresis
.
Anal Chem
1990
;
62
:
900
-
3
.
13.
Kasper
T J
,
Melera
M
,
Gozel
P
,
Brownlee
R G
.
Separation and detection of DNA by capillary electrophoresis
.
J Chromatogr
1988
;
458
:
303
-
12
.
14.
Srinivasan
K
,
Morris
S C
,
Firard
J E
,
Kline
M C
,
Reeder
D J
.
Enhanced detection of PCR products through use of TOTO and YOYO intercalating dyes with laser-induced fluorescence-capillary electrophoresis
.
Appl Theor Electrophoresis
1993
;
3
:
235
-
9
.
15.
Arakawa
H
,
Uetanaka
K
,
Maeda
M
,
Tsuji
A
,
Matsubara
Y
,
Narisawa
K
.
Analysis of polymerase chain reaction-product by capillary electrophoresis with laser-induced fluorescence detection and its application to the diagnosis of medium-chain acyl-coenzyme A dehydrogenase deficiency
.
J Chromatogr A
1994
;
680
:
517
-
23
.
16.
Ulfelder
K J
.
Concepts and principles of capillary electrophoresis related to the separation of polymerase chain reaction products
. In:
Rossomando
E
, editor.
High performance liquid chromatography in enzymatic analysis
, 2nd ed.
New York
,
John Wiley and Sons, Inc.
,
1998
;
41
-
63
.
17.
Comey
C T
,
Koons
B W
,
Presley
K W
,
Smerick
J B
,
Sobieralski
C A
,
Stanley
D M
, et al
DNA extraction strategies for amplified fragment length polymorphism analysis
.
J Forensic Sci
1994
;
39
:
1254
-
69
.
18.
Gill
P
,
Jeffreys
A J
,
Werrett
D J
.
Forensic application of DNA “fingerprints
.”
Nature
 0028-0836
1985
;
318
:
577
-
9
.
19.
Waye
J S
,
Presley
L
,
Budowle
B
,
Shutler
G G
,
Fourney
R M
.
A simple method for quantifying human genomic DNA in forensic specimen extracts
.
Bio Techniques
1989
;
7
:
852
-
5
.
20.
Budowle
B
,
Bacchtel
F S
,
Comey
C T
,
Giusti
A M
,
Klevan
L
.
Simple protocols for typing forensic biological evidence: chemiluminescent detection for human DNA quantitation and RFLP analyses and manual typing of PCR amplified polymorphisms
.
Electrophoresis
 0173-0835
1995
;
16
:
1559
-
67
.
21.
Perkin-Elmer Corporation
.
AmpFlSTR Profiler Plus User's Manual
. Version A.
Foster City, CA
.
1997
.
22.
Moretti
T R
,
Baumstark
A L
,
Defenbaugh
D A
,
Keys
K M
,
Smerick
J B
,
Budowle
B
.
Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples
.
J Forensic Sci
2001
;
46
(
3
):
223
-
236
.
23.
Luckey
J A
,
Norris
T B
,
Smith
L M
.
Analysis of resolution in DNA sequencing by capillary gel electrophoresis
.
J Phys Chem
1993
;
97
:
3067
-
75
.
24.
Perkin-Elmer Corporation
.
GeneScan reference guide
.
Foster City, CA
.
1997
.
25.
van der Schans
M J
,
Allen
J K
,
Wanders
B J
,
Guttman
A
.
Effects of sample matrix and injection plug on dsDNA migration in capillary electrophoresis
.
J Chromatogr A
1994
;
680
:
511
-
6
.
26.
Hjerten
S
.
Free zone electrophoresis
.
Chromatogr Rev
1967
;
9
:
122
-
219
.
27.
Butler
J M
,
McCord
B R
,
Jung
J M
,
Lee
J A
,
Budowle
B
,
Allen
R O
.
Application of dual internal standards for precise sizing of polymerase chain reaction products using capillary electrophoresis
.
Electrophoresis
 0173-0835
1995
;
16
:
974
-
80
.
28.
Wenz
H M
.
Capillary electrophoresis as a technique to analyze sequence-induced anomalously migrating DNA fragments
.
Nuc Acids Res
1994
;
22
:
4002
-
8
.
29.
Lu
W
,
Han
D S
,
Yuan
J
,
Andrieu
J M
.
Multi-target PCR analysis by capillary electrophoresis and laser-induced fluorescence
.
Nature
 0028-0836
1994
;
368
:
269
-
71
.
30.
Fasco
M J
,
Treanor
C P
,
Spivack
S
,
Figge
H L
,
Kaminsky
L S
.
Quantitative RNA-polymerase chain reaction-DNA analysis by capillary electrophoresis and laser-induced fluorescence
.
Anal Biochem
1995
;
224
:
140
-
7
.
31.
Budowle
B
,
Moretti
T R
,
Baumstark
A L
,
Defenbaugh
D A
,
Keys
K M
.
Population data on the 13 CODIS core short tandem repeat loci in African Americans, US Caucasians, Hispanics, Bahamians, Jamaicans and Trinidadians
.
J Forensic Sci
1999
;
44
:
1277
-
86
.
32.
Perkin-Elmer Corporation
.
AmpFlSTR Profiler User's Manual
. Version A.
Foster City, CA
.
1997
.
This content is only available via PDF.
You do not currently have access to this content.