Abstract

The combination of photographs taken at wavelengths at and bracketing the peak of a narrow absorbance band can lead to enhanced visualization of the substance causing the narrow absorbance band. This concept can be used to detect putative bloodstains by division of a linear photographic image taken at or near 415 nm with an image obtained by averaging linear photographs taken at or near 395 and 435 nm. Nonlinear images can also be background corrected by substituting subtraction for the division. This paper details experimental applications and limitations of this technique, including wavelength selection of the illuminant and at the camera. Characterization of a digital camera to be used in such a study is also detailed. Detection limits for blood using the three wavelength correction method under optimum conditions have been determined to be as low as 1 in 900 dilution, although on strongly patterned substrates blood diluted more than twenty-fold is difficult to detect. Use of only the 435 nm photograph to estimate the background in the 415 nm image lead to a twofold improvement in detection limit on unpatterned substrates compared with the three wavelength method with the particular camera and lighting system used, but it gave poorer background correction on patterned substrates.

References

1.
Wagner
JH
,
Miskelly
GM
.
Background correction in forensic photography I
.
Photography of blood under conditions of non-uniform illumination or variable substrate color theoretical aspects and proof of concept
.
J Forensic Sci
 0022-1198
2003
;
48
(
3
):
1
11
.
2.
Harboe
M
.
A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry
.
Scand J Clin Lab Investig
1959
;
11
:
66
70
.
3.
Holst
GC
.
CCD Arrays, Cameras, and Displays, 2nd ed
.
Bellingham
:
SPIE Optical Engineering Press
,
1998
.
4.
Holst
GC
.
CCD Arrays, Cameras, and Displays, 2nd ed
.
Bellingham
:
SPIE Optical Engineering Press
,
1998
. Ch. 4,
102
45
.
5.
Holst
GC
.
CCD Arrays, Cameras, and Displays, 2nd ed
.
Bellingham
:
SPIE Optical Engineering Press
,
1998
. Ch. 6,
182
200
.
6.
Holst
GC
.
CCD Arrays, Cameras, and Displays, 2nd ed
.
Bellingham
:
SPIE Optical Engineering Press
,
1998
Ch. 12,
338
70
.
7.
Russ
JC
.
The Image Processing and Analysis Cookbook
,
Asheville
:
Reindeer Graphics, Inc.
,
2001
.
8.
Holst
GC
.
Testing and Evaluation of Infrared Imaging Systems
, 2nd ed.
Bellingham
:
SPIE Optical Engineering Press
,
1998
.
9.
Stoilovic
M
.
Detection of semen and blood stains using Polilight as a light source
.
For Sci Int
 0379-0738
1991
;
51
:
289
96
.
10.
Cooper
K
.
Auckland Fingerprints Section, N.Z
.
Police 2002
, personal communication.
11.
International Committee for Standardisation in Haematology
.
Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobincyanide standard
. (4th edition),
J Clin Pathol
 0021-9746
1996
;
49
:
271
4
.
This content is only available via PDF.