Abstract

Laser-induced detection of fluorescent labeled PCR products and multi-wavelength detection (i.e., multicolor analysis) enables rapid generation of mtDNA sequencing profiles. Traditionally, polyacrylamide slab gels have been used as the electrophoretic medium for mtDNA sequencing in forensic analyses. Replacement of slab gel electrophoresis with capillary electrophoresis (CE) can facilitate automation of the analytical process. Automation and high throughput can be further enhanced by using multicapillary electrophoretic systems. The use of the ABI Prism® 3100 Genetic Analyzer (ABI 3100, Applied Biosystems, Foster City, CA) as well as the ABI Prism™ 310 Genetic Analyzer (ABI 310, Applied Biosystems, Foster City, CA) were evaluated for mtDNA sequencing capabilities and compared with sequencing results obtained on the platform currently in use in the FBI Laboratory (the ABI Prism™ 377 DNA Sequencer, ABI 377, Applied Biosystems, Foster City, CA). Various studies were performed to assess the utility of the ABI 3100, as well as the ABI 310 for mtDNA sequencing. The tests included: comparisons of results obtained among the ABI 3100, the ABI 310 and the ABI 377 instruments; comparisons of results obtained within and between capillary arrays; evaluation of capillary length; evaluation of sample injection time; evaluation of the resolution of mixtures/heteroplasmic samples; and evaluation of the sensitivity of detection of a minor component with reduced template on the ABI 3100. In addition, other studies were performed to improve sample preparation; these included: comparison of template suppression reagent (TSR, Applied Biosystems, Foster City, CA) versus formamide; the use of Performa™ DTR Gel Filtration Cartridges (Edge BioSystems™ Inc., Gaithersburg, MD) versus Centri-Sep Spin Columns (Princeton Separations, Adelphia, NJ) for product purification after cycle sequencing; and sample stability after denaturation. The data support that valid and reliable results can be obtained using either capillary electrophoresis instrument, and the quality of sequencing results are comparable to or better than those obtained from the ABI 377 instrument.

References

1.
Butler
JM
,
Allen
RO
,
McCord
BR
,
Jung
JM
,
Wlson
MR
,
Budowle
B
.
Quantitation of PCR products by capillary electrophoresis using laser fluorescence
.
J Chromatography
 0021-9673
1994
;
658
:
271
80
.
2.
Moretti
TR
,
Baumstark
AL
,
Defenbaugh
DA
,
Keys
KM
,
Smerick
J
,
Budowle
B
.
Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples
.
J Forensic Sci
 0022-1198
2001
;
46
(
3
):
647
60
.
3.
Melton
T
,
Nelson
K
.
Forensic mitochondrial DNA analysis: two years of commercial casework experience in the United States
.
Croatian Medical J
 0353-9504
2001
;
42
(
3
):
298
303
.
4.
Reynolds
R
,
Walker
K
,
Varlario
J
,
Allen
M
,
Clark
E
,
Erlich
H
.
Detection of sequence variation in the HVII region of the human mitochondrial genome in 689 individuals using immobilized sequence-specific oligonucleotide probes
.
J Forensic Sci
 0022-1198
2000
;
45
(
6
):
1210
31
.
5.
Wilson
MR
,
Polanskey
D
,
Butler
J
,
DiZinno
JA
,
Replogle
J
,
Budowle
B
.
Extraction, PCR, amplification and sequencing of mitochondrial DNA from human hair shafts
.
Biotechniques
 0736-6205
1995
;
16
:
662
8
.
6.
Wilson
MR
,
Polanskey
D
,
Replogle
J
,
DiZinno
JA
,
Budowle
B
.
A family exhibiting heteroplasmy in the human mitochondrial DNA control region reveals both somatic mosaicism and pronounced segregation of mitotypes
.
Hum Genet
 0015-816X
1997
;
100
:
167
71
.
7.
Wilson
MR
,
DiZinno
JA
,
Polanskey
D
,
Replogle
J
,
Budowle
B
.
Validation of mitochondrial DNA sequencing for forensic casework analysis
.
Int J Legal Med
 0937-9827
1995
;
108
:
68
74
.
8.
Stewart
JEB
,
Fisher
CL
,
Aagaard
PJ
,
Wilson
MR
,
Isenberg
AR
,
Polanskey
D
, et al
.
Length variation in HV2 of the human mitochondrial DNA control region
.
J Forensic Sci
 0022-1198
2001
;
46
(
4
):
862
70
.
This content is only available via PDF.