Workpiece localization has direct relations with many manufacturing automation applications. In order to gain accurate workpiece measurement by on-machine measurement system or coordinate measuring machines (CMM), the touch trigger probe is widely adopted. In spite of the high repeatability of the touch trigger probe, there are still error sources associated with the probe. In this paper, we will focus on probe radius compensation. We first show the sources of probe radius error. Then, several compensation methods in related papers are reviewed. After that, a new radius compensation method is proposed in this paper. Simulation and experimental results of probe radius compensation by different methods are given. It is shown that our proposed method has the best performance both in terms of compensation accuracy and computational time. The method is also implemented in a computer aided setup (CAS) system.
Skip Nav Destination
Article navigation
February 2003
Technical Papers
Probe Radius Compensation of Workpiece Localization
Zhenhua Xiong,
Zhenhua Xiong
School of Mechanical Engineering, Shanghai Jiaotong University, 1954 Hua Shan Road, Shanghai, 200030, P.R. China
Search for other works by this author on:
Zexiang Li, Associate Professor,
Zexiang Li, Associate Professor,
Dept. of EEE, Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
Zhenhua Xiong
School of Mechanical Engineering, Shanghai Jiaotong University, 1954 Hua Shan Road, Shanghai, 200030, P.R. China
Zexiang Li, Associate Professor,
Dept. of EEE, Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong
Contributed by the Manufacturing Engineering Division for publication in the JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING. Manuscript received October 2001; Revised April 2002. Associate Editor: E. C. DeMeter.
J. Manuf. Sci. Eng. Feb 2003, 125(1): 100-104 (5 pages)
Published Online: March 4, 2003
Article history
Received:
October 1, 2001
Revised:
April 1, 2002
Online:
March 4, 2003
Citation
Xiong, Z., and Li, Z. (March 4, 2003). "Probe Radius Compensation of Workpiece Localization ." ASME. J. Manuf. Sci. Eng. February 2003; 125(1): 100–104. https://doi.org/10.1115/1.1537260
Download citation file:
Get Email Alerts
Effect of Warpage Pattern of Printed Circuit Board on Solder Paste Volume in the Stencil Printing Process
J. Manuf. Sci. Eng (July 2025)
Experimental Study on Force and Surface Morphology of Additive Manufacturing FeCoNiCrAl0.5 High Entropy Alloy
J. Manuf. Sci. Eng (July 2025)
2024 Associate Editors
J. Manuf. Sci. Eng
Related Articles
Autonomously Generative CMM Part Programming for In-Process Inspection
J. Manuf. Sci. Eng (February,2003)
Quality and Inspection of Machining Operations: CMM Integration to the Machine Tool
J. Manuf. Sci. Eng (October,2009)
A Self-Calibration Method for Robotic Measurement System
J. Manuf. Sci. Eng (February,2000)
Related Proceedings Papers
Related Chapters
Accuracy-associated Models
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
Accuracy of an Axis
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
Field Experience with Rebar Probes to Monitor Performance of Sprayed Zinc Galvanic Anodes on Concrete
Techniques to Assess the Corrosion Activity of Steel Reinforced Concrete Structures