The interference fit is a common method for creating mechanical assemblies. When manufacturing the individual components to be assembled in this method, close dimensional control of the mating components is required in order to ensure that the amount of interference is sufficient to create a secure assembly, but not so great as to cause excessive stresses or failure of the individual components. In this work, we study interference fit connections in an assembly of human (cadaveric) cortical and cancellous bone, i.e., an allograft, used in spinal fusion surgeries. A difficulty encountered in this application is that, in addition to the machining steps, the assembly must go through subsequent sterilization and lyophilization, or freeze drying, processes that may affect the quality of the interference fit. This report examines the quality of the allograft interference fits using dimensional measurements of manufactured components at all stages of the manufacturing process, followed by examination for cracking and measurement of the pull-apart forces for assemblies. The experimental results are compared to finite element models of the interference fit and also to Monte Carlo models of the assembly using a simple thick-wall cylinder model. Experimental results show that the lyophilization process significantly affects the component dimensions, resulting in a much greater spread in interference values and likely leading to cracking and∕or loss of interference.
Skip Nav Destination
Article navigation
April 2008
Technical Briefs
The Influence of Process Variation on a Cortical Bone Interference Fit Pin Connection
Nathan A. Mauntler,
Nathan A. Mauntler
Department of Mechanical and Aerospace Engineering,
University of Florida
, Gainesville, FL 32611
Search for other works by this author on:
Tony L. Schmitz,
Tony L. Schmitz
Department of Mechanical and Aerospace Engineering,
University of Florida
, Gainesville, FL 32611
Search for other works by this author on:
John C. Ziegert
John C. Ziegert
Department of Mechanical Engineering,
Clemson University
, Clemson, SC 29607
Search for other works by this author on:
Nathan A. Mauntler
Department of Mechanical and Aerospace Engineering,
University of Florida
, Gainesville, FL 32611
Tony L. Schmitz
Department of Mechanical and Aerospace Engineering,
University of Florida
, Gainesville, FL 32611
John C. Ziegert
Department of Mechanical Engineering,
Clemson University
, Clemson, SC 29607J. Manuf. Sci. Eng. Apr 2008, 130(2): 024501 (7 pages)
Published Online: March 24, 2008
Article history
Received:
December 15, 2006
Revised:
December 31, 2007
Published:
March 24, 2008
Citation
Mauntler, N. A., Schmitz, T. L., and Ziegert, J. C. (March 24, 2008). "The Influence of Process Variation on a Cortical Bone Interference Fit Pin Connection." ASME. J. Manuf. Sci. Eng. April 2008; 130(2): 024501. https://doi.org/10.1115/1.2896103
Download citation file:
51
Views
Get Email Alerts
Cited By
A Review on Metallic Drilling Burrs: Geometry, Formation, and Effect on the Mechanical Strength of Metallic Assemblies
J. Manuf. Sci. Eng (April 2025)
A Generalized Machining Process Damping Model for Orthogonal Cutting
J. Manuf. Sci. Eng
Related Articles
A New External Fixator Design for Femoral Fracture Reduction
J. Med. Devices (June,2008)
A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing
J Biomech Eng (April,2009)
Simulation of Physiological Loading in Total Hip Replacements
J Biomech Eng (August,2006)
Related Proceedings Papers
Related Chapters
Part III Some Practical Advice
The Elements of Mechanical Design
STRUCTURAL RELIABILITY ASSESSMENT OF PIPELINE GIRTH WELDS USING GAUSSIAN PROCESS REGRESSION
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Gas-Fluidized Beds
Two-Phase Heat Transfer