The interference fit is a common method for creating mechanical assemblies. When manufacturing the individual components to be assembled in this method, close dimensional control of the mating components is required in order to ensure that the amount of interference is sufficient to create a secure assembly, but not so great as to cause excessive stresses or failure of the individual components. In this work, we study interference fit connections in an assembly of human (cadaveric) cortical and cancellous bone, i.e., an allograft, used in spinal fusion surgeries. A difficulty encountered in this application is that, in addition to the machining steps, the assembly must go through subsequent sterilization and lyophilization, or freeze drying, processes that may affect the quality of the interference fit. This report examines the quality of the allograft interference fits using dimensional measurements of manufactured components at all stages of the manufacturing process, followed by examination for cracking and measurement of the pull-apart forces for assemblies. The experimental results are compared to finite element models of the interference fit and also to Monte Carlo models of the assembly using a simple thick-wall cylinder model. Experimental results show that the lyophilization process significantly affects the component dimensions, resulting in a much greater spread in interference values and likely leading to cracking and∕or loss of interference.

1.
Huang
,
P.
,
Gupta
,
C.
,
Sarigul-Klijn
,
N.
, and
Hazelwood
,
S.
, 2006, “
Two In Vivo Surgical Approches for Lumbar Corpectomy Using Allograft and a Metallic Implant: A Controlled Clinical and Biomechanical Study
,”
The Spine Journal
,
6
, pp.
648
658
.
2.
Komotar
,
R.
,
Mocco
,
J.
, and
Kaiser
,
M.
, 2006, “
Surgical Management of Cervical Myelopathy: Indications and Techniques for Laminectomy and Fusion
,”
The Spine Journal
,
6
, pp.
252S
267S
.
3.
Huiskes
,
R.
, 1982, “
On the Modeling of Long Bones in Structural Analyses
,”
J. Biomech.
0021-9290,
15
(
1
), pp.
65
69
.
4.
Reilly
,
D.
, and
Burstein
,
A.
, 1975, “
The Elastic Modulus and Ultimate Properties of Compact Bone Tissue
,”
J. Biomech.
0021-9290,
8
(
6
), pp.
393
396
.
5.
Yoon
,
H.
, and
Katz
,
J.
, 1976, “
Ultrasonic Wave Propagation in Human Cortical Bone II: Measurements of Elastic Properties and Micro-Hardness
,”
J. Biomech.
0021-9290,
9
, pp.
459
462
.
6.
Shigley
,
J.
, and
Mischke
,
C.
, 2001,
Mechanical Engineering Design
,
McGraw-Hill
,
New York
.
7.
Boresi
,
A.
, and
Schmidt
,
R.
, 2003,
Advanced Mechanics of Materials
,
Wiley
,
Hoboken, NJ
.
8.
Bianchi
,
J.
, 1999, “
Design and Mechanical Behavior of the MD Series of Bone Dowels
,” University of Florida, Gainesville, FL, Doctor of Philosophy.
You do not currently have access to this content.