The management of health through daily monitoring of respiration is of major importance for early diagnosis to prevent respiratory and circulatory diseases. Such daily health monitoring is possible only if the monitoring system is physically and psychologically noninvasive. However, current unconstrained measurement methods cannot distinguish chest and abdominal movements in diagnosing sleep apnea. In this study, a flexible and stretchable tactile sensor sheet was developed to measure the static body pressure of a subject who lies on it and measure the pressure fluctuations induced by respiration or respiratory efforts. The results were compared with the measurements by band sensors that are widely used for measuring chest and abdominal movements in clinic. It was demonstrated that the sensor sheet can distinguish chest and abdominal movements in a supine position. The reasons why the pressure fluctuations measured by the sensor sheet are antiphase with the outputs of band sensors are discussed using a simple dynamic model.
Skip Nav Destination
Article navigation
December 2016
Research-Article
Unconstrained Measurement of Respiration Motions of Chest and Abdomen Using a Tactile Sensor Sheet in Supine Position on Bed
Shijie Guo,
Shijie Guo
School of Mechanical Engineering,
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: guoshijie@hebut.edu.cn
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: guoshijie@hebut.edu.cn
Search for other works by this author on:
Kazuya Matsuo,
Kazuya Matsuo
School of Engineering,
Kyushu Institute of Technology,
1-1, Sensui-cho, Tobata-ku,
Kitakyushu-shi, Fukuoka-ken 804-8550, Japan
e-mail: matsuo@cntl.kyutech.ac.jp
Kyushu Institute of Technology,
1-1, Sensui-cho, Tobata-ku,
Kitakyushu-shi, Fukuoka-ken 804-8550, Japan
e-mail: matsuo@cntl.kyutech.ac.jp
Search for other works by this author on:
Jinyue Liu,
Jinyue Liu
School of Mechanical Engineering,
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: ljy@hebut.edu.cn
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: ljy@hebut.edu.cn
Search for other works by this author on:
Toshiharu Mukai
Toshiharu Mukai
Faculty of Science and Technology,
Meijo University,
1-501 Shiogamaguchi, Tempaku-ku,
Nagoya 468-8502, Japan
e-mail: mukai@meijo-u.ac.jp
Meijo University,
1-501 Shiogamaguchi, Tempaku-ku,
Nagoya 468-8502, Japan
e-mail: mukai@meijo-u.ac.jp
Search for other works by this author on:
Shijie Guo
School of Mechanical Engineering,
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: guoshijie@hebut.edu.cn
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: guoshijie@hebut.edu.cn
Kazuya Matsuo
School of Engineering,
Kyushu Institute of Technology,
1-1, Sensui-cho, Tobata-ku,
Kitakyushu-shi, Fukuoka-ken 804-8550, Japan
e-mail: matsuo@cntl.kyutech.ac.jp
Kyushu Institute of Technology,
1-1, Sensui-cho, Tobata-ku,
Kitakyushu-shi, Fukuoka-ken 804-8550, Japan
e-mail: matsuo@cntl.kyutech.ac.jp
Jinyue Liu
School of Mechanical Engineering,
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: ljy@hebut.edu.cn
Hebei University of Technology,
8, Dingzigu Yihaolu, Hongqiao-qu,
Tianjin 300132, China
e-mail: ljy@hebut.edu.cn
Toshiharu Mukai
Faculty of Science and Technology,
Meijo University,
1-501 Shiogamaguchi, Tempaku-ku,
Nagoya 468-8502, Japan
e-mail: mukai@meijo-u.ac.jp
Meijo University,
1-501 Shiogamaguchi, Tempaku-ku,
Nagoya 468-8502, Japan
e-mail: mukai@meijo-u.ac.jp
Manuscript received February 2, 2016; final manuscript received July 30, 2016; published online September 12, 2016. Assoc. Editor: Michael Eggen.
J. Med. Devices. Dec 2016, 10(4): 041008 (7 pages)
Published Online: September 12, 2016
Article history
Received:
February 2, 2016
Revised:
July 30, 2016
Citation
Guo, S., Matsuo, K., Liu, J., and Mukai, T. (September 12, 2016). "Unconstrained Measurement of Respiration Motions of Chest and Abdomen Using a Tactile Sensor Sheet in Supine Position on Bed." ASME. J. Med. Devices. December 2016; 10(4): 041008. https://doi.org/10.1115/1.4034465
Download citation file:
Get Email Alerts
Cited By
Related Articles
Origami-Layer-Jamming Deployable Surgical Retractor With Variable Stiffness and Tactile Sensing
J. Mechanisms Robotics (June,2020)
Data Communication Pathway for Sensing Guidewire at Proximal Side: A Review
J. Med. Devices (June,2017)
SOMNUS: A Sleep-Measuring Shirt Based on Chest Expansion and Respiratory Patterns
J. Med. Devices (June,2011)
Designing an Optical Bendloss Sensor for Clinical ForcMeasurement
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Design of a Finger-Tip Flexible Tactile Sensor for Dexterous Robot Hand and the Crosstalk Effect Analysis
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Research of a Novel Intelligent Safety Device
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
Sleep Deprivation Effect on Human Performance: A Meta-Analysis Approach (PSAM-0010)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)