This paper reports the design, development, and initial evaluation of a robotic laparoscopic clipping tool for single manipulator wound closure and anastomosis (tubular reconnection). The tool deploys biodegradable clips and clasps with the goal of (i) integrating grasping and suturing into a single device for single hand or manipulator use, (ii) applying the equivalent of interrupted sutures without the need of managing suture thread, and (iii) allowing for full six degrees-of-freedom (DOFs) laparoscopic control when mounted on a robot arm. The specifications, workflow, and detailed design of the robotic laparoscopic tool and injection molded bio-absorbable T shaped clip and locking clasp are reported. The clipping tool integrates forceps to grab and stabilize tissue and a clip and clasp applier to approximate and fixate the tissue. A curved needle is advanced on a circular needle path and picks up and drags clips through tissue. The clip is then tightened through the tissue and a clasp is clamped around the clip, before the clip is released from the needle. Results of several bench test runs of the tool show: (a) repeatable circular needle drive, (b) successful pick-up and deployment of clips, (c) successful shear of the clip to release the clip from the needle, and (d) closure of clasp on clip with an average of 2.0 N holding force. These data indicate that the robotic laparoscopic clipping tool could be used for laparoscopic wound closure and anastomosis.

References

1.
Weiser
,
T. G.
,
Regenbogen
,
S. E.
,
Thompson
,
K. D.
,
Haynes
,
A. B.
,
Lipsitz
,
S. R.
,
Berry
,
W. R.
, and
Gawande
,
A. A.
,
2008
, “
An Estimation of the Global Volume of Surgery: A Modelling Strategy Based on Available Data
,”
Lancet
,
372
(
9633
), pp.
139
144
.
2.
Kirkup
,
J. R.
,
1981
, “
The History and Evolution of Surgical Instruments—I: Introduction
,”
Ann. R. Coll. Surg. Engl.
,
63
(
4
), pp.
279
285
.
3.
Chapron
,
C.
,
Querleu
,
D.
,
Bruhat
,
M. A.
,
Madelenat
,
P.
,
Fernandez
,
H.
,
Pierre
,
F.
, and
Dubuisson
,
J. B.
,
1998
, “
Surgical Complications of Diagnostic and Operative Gynaecological Laparoscopy: A Series of 29,966 Cases
,”
Hum. Reprod.
,
13
(
4
), pp.
867
872
.
4.
Fullum
,
T. M.
,
Ladapo
,
J. A.
,
Borah
,
B. J.
, and
Gunnarsson
,
C. L.
,
2010
, “
Comparison of the Clinical and Economic Outcomes Between Open and Minimally Invasive Appendectomy and Colectomy: Evidence From a Large Commercial Payer Database
,”
Surg. Endoscopy
,
24
(
4
), pp.
845
853
.
5.
Noel
,
J. K.
,
Fahrbach
,
K.
,
Estok
,
R.
,
Cella
,
C.
,
Frame
,
D.
,
Linz
,
H.
,
Cima
,
R. R.
,
Dozois
,
E. J.
, and
Senagore
,
A. J.
,
2007
, “
Minimally Invasive Colorectal Resection Outcomes: Short-Term Comparison With Open Procedures
,”
J. Am. Coll. Surg.
,
204
(
2
), pp.
291
307
.
6.
Lau
,
W. Y.
,
Leung
,
K. L.
,
Kwong
,
K. H.
,
Davey
,
I. C.
,
Robertson
,
C.
,
Dawson
,
J. J.
,
Chung
,
S. C.
, and
Li
,
A. K.
,
1996
, “
A Randomized Study Comparing Laparoscopic Versus Open Repair of Perforated Peptic Ulcer Using Suture or Sutureless Technique
,”
Ann. Surg.
,
224
(
2
), pp.
131
138
.
7.
Neo
,
E. L.
,
Patkin
,
M.
, and
Watson
,
D. I.
,
2004
, “
Suturing Efficiency During Hiatal Repair for Laparoscopic Fundoplication
,”
ANZ J. Surg.
,
74
(
1–2
), pp.
13
17
.
8.
Marzouk
,
K.
,
Lawen
,
J.
,
Alwayn
,
I.
, and
Kiberd
,
B. A.
,
2013
, “
The Impact of Vascular Anastomosis Time on Early Kidney Transplant Outcomes
,”
Transplant. Res.
,
2
(
1
), p. 8.
9.
Hollands
,
C. M.
,
Dixey
,
L. N.
, and
Torma
,
M. J.
,
2001
, “
Technical Assessment of Porcine Enteroenterostomy Performed With ZEUS Robotic Technology
,”
J. Pediatr. Surg.
,
36
(
8
), pp.
1231
1233
.
10.
Dion
,
Y. M.
,
Hartung
,
O.
,
Gracia
,
C.
, and
Doillon
,
C.
,
1999
, “
Experimental Laparoscopic Aortobifemoral Bypass With End-to-Side Aortic Anastomosis
,”
Surg. Laparoscopic Endoscopy
,
9
(
1
), pp.
35
38
.
11.
Hoznek
,
A.
,
Salomon
,
L.
,
Rabii
,
R.
,
Ben Salama
,
M. R.
,
Cicco
,
A.
,
Antiphon
,
P.
, and
Abbou
,
C. C.
,
2000
, “
Vesicourethral Anastomosis During Laparoscopic Radical Prostatectomy: The Running Suture Method
,”
J. Endourology
,
14
(
9
), pp.
749
753
.
12.
Seo
,
S. H.
,
Kim
,
K. H.
,
Kim
,
M. C.
,
Choi
,
H. J.
, and
Jung
,
G. J.
,
2012
, “
Comparative Study of Hand-Sutured Versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy
,”
J. Gastric Cancer
,
12
(
2
), pp.
120
125
.
13.
Gonzalez
,
R.
,
Lin
,
E.
,
Venkatesh
,
K. R.
,
Bowers
,
S. P.
, and
Smith
,
C. D.
,
2003
, “
Gastrojejunostomy During Laparoscopic Gastric Bypass: Analysis of 3 Techniques
,”
Arch. Surg.
,
138
(
2
), pp.
181
184
.
14.
Nguyen
,
N. T.
, and
Wolfe
,
B. M.
,
2000
, “
Hypopharyngeal Perforation During Laparoscopic Roux-En-Y Gastric Bypass
,”
Obes. Surg.
,
10
(
1
), pp.
64
67
.
15.
de la Torre
,
R. A.
, and
Scott
,
J. S.
,
1999
, “
Laparoscopic Roux-En-Y Gastric Bypass: A Totally Intra-Abdominal Approach–Technique and Preliminary Report
,”
Obes. Surg.
,
9
(
5
), pp.
492
498
.
16.
Adams
,
J. B.
,
Schulam
,
P. G.
,
Moore
,
R. G.
,
Partin
,
A. W.
, and
Kavoussi
,
L. R.
,
1995
, “
New Laparoscopic Suturing Device: Initial Clinical Experience
,”
Urology
,
46
(
2
), pp.
242
245
.
17.
Hashemi
,
L.
,
Hart
,
S.
,
Craig
,
S.
,
Geraci
,
D.
, and
Shatskih
,
E.
,
2011
, “
Effect of an Automated Suturing Device on Cost and Operating Room Time in Laparoscopic Total Abdominal Hysterectomies
,”
J. Minimally Invasive Gynecol.
,
18
(
6
), pp.
S96
S97
.
18.
Harold
,
K. L.
,
Matthews
,
B. D.
,
Backus
,
C. L.
,
Pratt
,
B. L.
, and
Heniford
,
B. T.
,
2002
, “
Prospective Randomized Evaluation of Surgical Resident Proficiency With Laparoscopic Suturing After Course Instruction
,”
Surg. Endoscopy
,
16
(
12
), pp.
1729
1731
.
19.
Leonard
,
S.
,
Wu
,
K. L.
,
Kim
,
Y.
,
Krieger
,
A.
, and
Kim
,
P. C. W.
,
2014
, “
Smart Tissue Anastomosis Robot (STAR): A Vision-Guided Robotics System for Laparoscopic Suturing
,”
IEEE Trans. Biomed. Eng.
,
61
(
4
), pp.
1305
1317
.
20.
Shademan
,
A.
,
Decker
,
R. S.
,
Opfermann
,
J. D.
,
Leonard
,
S.
,
Krieger
,
A.
, and
Kim
,
P. C.
,
2016
, “
Supervised Autonomous Robotic Soft Tissue Surgery
,”
Sci. Transl. Med.
,
8
(
337
), p.
337ra64
.
21.
Waninger
,
J.
,
Kauffmann
,
G.
,
Shah
,
I.
, and
Farthmannm
,
E.
,
1992
, “
Influence of the Distance Between Interrupted Sutures and the Tension of Sutures on the Healing of Experimental Colonic Anastomosis
,”
Am. J. Surg.
,
163
(
3
), pp.
319
323
.
You do not currently have access to this content.