Abstract

Although laparoscopy has revolutionized modern medicine, its training remains long and complex due to reduced haptic feedback and loss of depth perception. Training also poses an ethical challenge when performed on living patients, and access to cadavers is becoming rare and difficult. In the early 2000s, medical simulators began to appear to help mitigate these problems: virtual reality simulators (VRS) and physical reality simulators (PRS). Current VRS can provide guidance and performance evaluation with fewer instructors but are expensive and bulky. PRS, on the other hand, are less expensive, compact and offer haptic feedback through real physical interactions with mockup objects. However, they require guidance from an instructor, and cannot provide objective assessment or complex and realistic surgical scenarios. This paper assesses the potential of a VRS based on magneto-rheological (MR) actuators that could offer the haptic capabilities of current VRS with the size envelopes of PRS. Technical specifications for a laparoscopic VRS are extracted from the literature, a prototype is built and evaluated experimentally. In addition, three simulation scenarios are built and presented to surgeons to confirm simulation capabilities. In its current form, the MR-powered prototype is shown to meet targeted functional specifications but future work is needed to reduce friction, reduce size, and optimize packaging.

References

1.
Sánchez-Margallo
,
F. M.
,
Sánchez-Margallo
,
J. A.
, and
Usón
,
J.
,
2019
,
Introductory Chapter: Addressing the Challenges of Laparoscopic Surgery
(
Recent Advances in Laparoscopic Surgery
), IntechOpen, London, UK.
2.
Anastakis
,
D. J.
,
Regehr
,
G.
,
Reznick
,
R. K.
,
Cusimano
,
M.
,
Murnaghan
,
J.
,
Brown
,
M.
, and
Hutchison
,
C.
,
1999
, “
Assessment of Technical Skills Transfer From the Bench Training Model to the Human Model
,”
Am. J. Surg.
,
177
(
2
), pp.
167
170
.10.1016/S0002-9610(98)00327-4
3.
Consky
,
M.
,
2022
, “
Some Medical Schools in Canada Face Cadaver Shortage
,” CTV News, Toronto, ON, Canada, accessed Jan. 4, 2023, https://www.ctvnews.ca/health/some-medical-schools-in-canada-face-cadaver-shortage-1.5978179
4.
Dubinski
,
K.
,
2022
, “
Some Canadian Med Schools Are Running Low on a Precious Resource – Cadavers
,” CBC, Toronto, ON, Canada, accessed Jan. 4, 2023, https://www.cbc.ca/news/canada/london/human-cadaver-shortage-1.6503714
5.
Haederle
,
M.
,
2022
, “
UNM Anatomy Lab Runs Short of Donated Cadavers
,” Body of Learning, Albuquerque, NM, accessed Sept. 13, 2023, https://hsc.unm.edu/news/2022/03/anatomy-lab-short-of-donated-cadavers.html
6.
Andreatta
,
P. B.
,
Woodrum
,
D. T.
,
Birkmeyer
,
J. D.
,
Yellamanchilli
,
R. K.
,
Doherty
,
G. M.
,
Gauger
,
P. G.
, and
Minter
,
R. M.
,
2006
, “
Laparoscopic Skills Are Improved With LapMentor™ Training
,”
Ann. Surg.
,
243
(
6
), pp.
854
863
.10.1097/01.sla.0000219641.79092.e5
7.
Duffy
,
A. J.
,
Hogle
,
N. J.
,
McCarthy
,
H.
,
Lew
,
J. I.
,
Egan
,
A.
,
Christos
,
P.
, and
Fowler
,
D. L.
,
2005
, “
Construct Validity for the LAPSIM Laparoscopic Surgical Simulator
,”
Surg. Endoscopy Other Interventional Tech.
,
19
(
3
), pp.
401
405
.10.1007/s00464-004-8202-9
8.
Iwata
,
N.
,
Fujiwara
,
M.
,
Kodera
,
Y.
,
Tanaka
,
C.
,
Ohashi
,
N.
,
Nakayama
,
G.
,
Koike
,
M.
, and
Nakao
,
A.
,
2011
, “
Construct Validity of the LapVR Virtual-Reality Surgical Simulator
,”
Surg. Endoscopy
,
25
(
2
), pp.
423
428
.10.1007/s00464-010-1184-x
9.
Hong
,
M.
,
Rozenblit
,
J. W.
, and
Hamilton
,
A. J.
,
2021
, “
Simulation-Based Surgical Training Systems in Laparoscopic Surgery: A Current Review
,”
Virtual Reality
, 25(2), pp.
491
510
.10.1007/s10055-020-00469-z
10.
Sharma
,
M.
, and
Horgan
,
A.
,
2012
, “
Comparison of Fresh-Frozen Cadaver and High-Fidelity Virtual Reality Simulator as Methods of Laparoscopic Training
,”
World J. Surg.
,
36
(
8
), pp.
1732
1737
.10.1007/s00268-012-1564-6
11.
Pham
,
A.-D.
, and
Ahn
,
H.-J.
,
2018
, “
High Precision Reducers for Industrial Robots Driving 4th Industrial Revolution: State of Arts, Analysis, Design, Performance Evaluation and Perspective
,”
Int. J. Precis. Eng. Manuf. Green Technol.
,
5
(
4
), pp.
519
533
.10.1007/s40684-018-0058-x
12.
Slucock
,
T.
,
2022
, “
A Systematic Review of Low-Cost Actuator Implementations for Lower-Limb Exoskeletons: A Technical and Financial Perspective
,”
J. Intell. Rob. Syst.
,
106
(
1
), p.
3
.10.1007/s10846-022-01695-0
13.
GERATI
, 2022, “
Laparoscopic Trainer Box Laparoscopic Trainer Simulator
,” Gerati, Sialkot, Pakistan, accessed Dec. 20, 2022, https://www.gerati.com/product/gerati-laparoscopic-trainer-box/
14.
Fu
,
Y.
,
Bo
,
P.
,
Li
,
K.
, and
Wang
,
S.
,
2007
, “
Laparoscopic Robot Design and Kinematic Validation
,”
2006 IEEE International Conference on Robotics and Biomimetics
, Kunming, China, Dec. 17–20, pp.
1426
1431
.10.1109/ROBIO.2006.340138
15.
Abbott
,
J. J.
, and
Okamura
,
A. M.
,
2004
, “
A Sufficient Condition for Passive Virtual Walls With Quantization Effects
,”
ASME
Paper No. IMECE2004-59805.10.1115/IMECE2004-59805
16.
Brooks
,
T.
,
1990
, “
Telerobotic Response Requirements
,”
IEEE International Conference on Systems, Man, and Cybernetics Conference Proceedings
, Los Angeles, CA, Nov. 4–7, pp.
113
120
.10.1109/ICSMC.1990.142071
17.
Toledo
,
L.
,
Gossot
,
D.
,
Fritsch
,
S.
,
Revillon
,
Y.
, and
Reboulet
,
C.
,
1999
, “
Study of Sustained Forces and the Working Space of Endoscopic Surgery Instruments
,”
Ann. Chir.
,
53
(
7
), pp.
587
597
.https://pubmed.ncbi.nlm.nih.gov/10520498/
18.
Picod
,
G.
,
Jambon
,
A. C.
,
Vinatier
,
D.
, and
Dubois
,
P.
,
2005
, “
What Can the Operator Actually Feel When Performing a Laparoscopy?
,”
Surg. Endoscopy Other Interventional Tech.
,
19
(
1
), pp.
95
100
.10.1007/s00464-003-9330-3
19.
Choi
,
S.
, and
Tan
,
H.
,
2004
, “
Effect of Update Rate on Perceived Instability of Virtual Haptic Texture
,” IEEE/RSJ International Conference on Intelligent Robots and Systems (
IROS
) (IEEE Cat. No. 04CH37566), Vol. 4, Sendai, Japan, Sept. 28–Oct. 2, pp.
3577
3582
.10.1109/IROS.2004.1389970
20.
Overtoom
,
E. M.
,
Horeman
,
T.
,
Jansen
,
F.-W.
,
Dankelman
,
J.
, and
Schreuder
,
H. W. R.
,
2019
, “
Haptic Feedback, Force Feedback, and Force-Sensing in Simulation Training for Laparoscopy: A Systematic Overview
,”
J. Surg. Educ.
,
76
(
1
), pp.
242
261
.10.1016/j.jsurg.2018.06.008
21.
Lebel
,
L.-P.
,
Verreault
,
J.-A.
,
Bigué
,
J.-P. L.
,
Plante
,
J.-S.
, and
Girard
,
A.
,
2021
,
Performance Study of Low Inertia Magnetorheological Actuators for Kinesthetic Haptic Devices
,
Montreal, QC, Canada
, p.
6
.
22.
Hema Latha
,
K.
,
Usha Sri
,
P.
, and
Seetharamaiah
,
N.
,
2017
, “
Design and Manufacturing Aspects of Magneto-Rheological Fluid (MRF) Clutch
,”
Mater. Today: Proc.
,
4
(
2
), pp.
1525
1534
.10.1016/j.matpr.2017.01.175
23.
Chouinard
,
P.
,
Begin
,
M.-A.
,
Fortin
,
J. M.
,
Berry
,
A.
,
Masson
,
P.
, and
Plante
,
J.-S.
,
2018
, “
Preventing Lower Back Pain Among Truck Drivers: Design and Performance of a Controlled Slippage Magnetorheological Actuator for an Active Seat Suspension
,”
ASME
Paper No. DETC2018-85681.10.1115/DETC2018-85681
24.
Bégin
,
M.-A.
,
Chouinard
,
P.
,
Lebel
,
L.-P.
,
Masson
,
P.
,
Pasco
,
Y.
,
Plante
,
J.-S.
, and
Berry
,
A.
,
2018
, “
Experimental Assessment of a Controlled Slippage Magnetorheological Actuator for Active Seat Suspensions
,”
IEEE/ASME Trans. Mechatronics
,
23
(
4
), pp.
1800
1810
.10.1109/TMECH.2018.2836351
25.
GraMag
, 2022, “
SteadyRide | Most Comfortable Semi-Truck Seats
,” GraMag, London, OH, accessed Jan. 18, 2023, https://gramag.com/steadyride/
26.
Hogan
,
N.
,
1985
, “
Impedance Control: An Approach to Manipulation: Part II–Implementation
,”
ASME J. Dyn. Syst., Meas., Control
,
107
(
1
), pp.
8
16
.10.1115/1.3140713
27.
Makkar
,
C.
,
Dixon
,
W.
,
Sawyer
,
W.
, and
Hu
,
G.
,
2005
, “
A New Continuously Differentiable Friction Model for Control Systems Design
,”
Proceedings of the 2005 IEEE/ASME International Conference on Advanced Intelligent Mechatronics
, Monterey, CA, July 24–28, pp.
600
605
.10.1109/AIM.2005.1511048
28.
Faure
,
F.
,
Duriez
,
C.
,
Delingette
,
H.
,
Allard
,
J.
,
Gilles
,
B.
,
Marchesseau
,
S.
,
Talbot
,
H.
,
Courtecuisse
,
H.
,
Bousquet
,
G.
,
Peterlik
,
I.
, and
Cotin
,
S.
,
2012
, “
SOFA: A Multi-Model Framework for Interactive Physical Simulation
,”
Soft Tissue Biomechanical Modeling for Computer Assisted Surgery
(
Studies in Mechanobiology, Tissue Engineering and Biomaterials)
,
Y.
Payan
, ed., Vol.
11
, Springer, New York, pp.
283
321
.
29.
Cornut
,
O.
,
2022
, “
Dear ImGui
,” Omar Cornut, Paris, France, accessed Oct. 20, 2022, https://github.com/ocornut/imgui
30.
Fedorov
,
A.
,
Beichel
,
R.
,
Kalpathy-Cramer
,
J.
,
Finet
,
J.
,
Fillion-Robin
,
J.-C.
,
Pujol
,
S.
,
Bauer
,
C.
,
Jennings
,
D.
,
Fennessy
,
F.
,
Sonka
,
M.
,
Buatti
,
J.
,
Aylward
,
S.
,
Miller
,
J.
,
Pieper
,
S.
, and
Kikinis
,
R.
,
2012
, “
3D Slicer as an Image Computing Platform for the Quantitative Imaging Network
,”
Magn. Reson. Imaging
, 30(9), pp.
1323
1341
.10.1016/j.mri.2012.05.001
31.
The Blender Foundation,
2022
, “
Blender
,” The Blender Foundation, Amsterdam, The Netherlands, accessed Oct. 21, 2022, https://www.blender.org/
32.
Cignoni
,
P.
,
Callieri
,
M.
,
Corsini
,
M.
,
Dellepiane
,
M.
,
Ganovelli
,
F.
, and
Ranzuglia
,
G.
,
2008
, “
MeshLab: An Open-Source Mesh Processing Tool
,”
Eurographics Italian Chapter Conference
,
V.
Scarano
,
R. D.
Chiara
, and
U.
Erra
, eds.,
The Eurographics Association
, Eindhoven, The Netherlands.
33.
Geuzaine
,
C.
, and
Remacle
,
J.-F.
,
2009
, “
Gmsh: A 3-D Finite Element Mesh Generator With Built-in Pre- and Post-Processing Facilities: The GMSH PAPER
,”
Int. J. Numer. Methods Eng.
,
79
(
11
), pp.
1309
1331
.10.1002/nme.2579
34.
The GIMP Development Team,
2019
, “
Gimp
,” The GIMP Development Team, accessed Sept. 13, 2023, https://www.gimp.org
You do not currently have access to this content.