Abstract

Telesurgery applications in laparoscopic surgeries are limited by the need for a surgeon to manually insert the trocar for access to the abdominal cavity. This feasibility study aims to solve this by capitalizing on the biomechanical properties of the abdominal wall to introduce the robotic automated peritoneal insertion device (RAPID), a novel mechanism employing a purely mechanical indication system for accessing the abdominal cavity. The RAPID leverages differences in insufflation pressure between the abdominal wall and the abdominal cavity to indicate entry. In the initial phase of this research, cadaver testing showed that concomitant insufflation can be used to identify peritoneal cavity access in humans, validating a previous finding in a porcine study. Using an optimal pressure value determined from the previous porcine study, the RAPID was then validated in live porcine models. The system operated correctly in 19 out of 21 placements, affirming the feasibility of the entry indication system. This shows that the RAPID can accurately and automatically indicate entry of the trocar into the abdominal cavity. This advancement has the potential to automate initial and subsequent trocar insertions, thus removing one more constraint on laparoscopic telesurgery.

References

1.
Sood
,
A.
,
Meyer
,
C. P.
,
Abdollah
,
F.
,
Sammon
,
J. D.
,
Sun
,
M.
,
Lipsitz
,
S. R.
,
Hollis
,
M.
,
Weissman
,
J. S.
,
Menon
,
M.
, and
Trinh
,
Q.-D.
,
2017
, “
Minimally Invasive Surgery and Its Impact on 30-Day Postoperative Complications, Unplanned Readmissions and Mortality
,”
Br. J. Surg.
,
104
(
10
), pp.
1372
1381
.10.1002/bjs.10561
2.
Robinson
,
T. N.
, and
Stiegmann
,
G. V.
,
2004
, “
Minimally Invasive Surgery
,”
Endoscopy
,
36
(
1
), pp.
48
51
.10.1055/s-2004-814113
3.
Choi
,
P. J.
,
Oskouian
,
R. J.
, and
Tubbs
,
R. S.
,
2018
, “
Telesurgery: Past, Present, and Future
,”
Cureus
,
10
(
5
), p.
e2716
.10.7759/cureus.2716
4.
Mohan
,
A.
,
Wara
,
U. U.
,
Arshad Shaikh
,
M. T.
,
Rahman
,
R. M.
, and
Zaidi
,
Z. A.
,
2021
, “
Telesurgery and Robotics: An Improved and Efficient Era
,”
Cureus
,
13
(
3
), p.
e14124
.10.7759/cureus.14124
5.
Mishra
,
R. K.
,
2013
,
Textbook of Practical Laparoscopic Surgery
,
JP Medical Ltd.
, New Delhi, India.
6.
Picozzi
,
P.
,
Nocco
,
U.
,
Puleo
,
G.
,
Labate
,
C.
, and
Cimolin
,
V.
,
2023
, “
Telemedicine and Robotic Surgery: A Narrative Review to Analyze Advantages, Limitations and Future Developments
,”
Electronics
,
13
(
1
), p.
124
.10.3390/electronics13010124
7.
Xia
,
S.-B.
, and
Lu
,
Q.-S.
,
2021
, “
Development Status of Telesurgery Robotic System
,”
Chin. J. Traumatol.
,
24
(
3
), pp.
144
147
.10.1016/j.cjtee.2021.03.001
8.
Renda
,
A.
, and
Vallancien
,
G.
,
2003
, “
Principles and Advantages of Robotics in Urologic Surgery
,”
Curr. Urol. Rep.
,
4
(
2
), pp.
114
118
.10.1007/s11934-003-0037-8
9.
Reynolds
,
R. E.
,
Wankum
,
B. P.
,
Crimmins
,
S. J.
,
Carlson
,
M. A.
, and
Terry
,
B. S.
,
2022
, “
Preperitoneal Insufflation Pressure of the Abdominal Wall in a Porcine Model
,”
Surg. Endosc.
,
36
(
1
), pp.
300
306
.10.1007/s00464-020-08275-z
10.
Mikhail
,
E.
,
Tamhane
,
N.
,
Sarkar
,
P.
,
Sappenfield
,
E.
,
Tanner
,
J. P.
, and
Imudia
,
A. N.
,
2019
, “
Laparoscopic Entry Technique Using a Veress Needle Insertion With and Without Concomitant CO2 Insufflation: A Randomized Controlled Trial
,”
J. Minimally Invasive Gynecol.
,
26
(
7
), pp.
1383
1388
.10.1016/j.jmig.2019.02.011
11.
Malbrain
,
M. L. N. G.
,
2009
, “
Different Techniques to Measure Intra-Abdominal Pressure (IAP): Time for a Critical Re-Appraisal
,”
Applied Physiology in Intensive Care Medicine
,
G.
Hedenstierna
,
J.
Mancebo
,
L.
Brochard
, and
M. R.
Pinsky
, eds.,
Springer
,
Berlin, Germany
, pp.
143
157
.
12.
Thepsuwan
,
J.
,
Huang
,
K.-G.
,
Wilamarta
,
M.
,
Adlan
,
A.-S.
,
Manvelyan
,
V.
, and
Lee
,
C.-L.
,
2013
, “
Principles of Safe Abdominal Entry in Laparoscopic Gynecologic Surgery
,”
Gynecol. Minimally Invasive Ther.
,
2
(
4
), pp.
105
109
.10.1016/j.gmit.2013.07.003
13.
Krishnakumar
,
S.
, and
Tambe
,
P.
,
2009
, “
Entry Complications in Laparoscopic Surgery
,”
J. Gynecol. Endosc. Surg.
,
1
(
1
), pp.
4
11
.10.4103/0974-1216.51902
14.
Alkatout
,
I.
,
2017
, “
Complications of Laparoscopy in Connection With Entry Techniques
,”
J. Gynecol. Surg.
,
33
(
3
), pp.
81
91
.10.1089/gyn.2016.0111
15.
Raimondo
,
D.
,
Raffone
,
A.
,
Travaglino
,
A.
,
Ferla
,
S.
,
Maletta
,
M.
,
Rovero
,
G.
,
Renzulli
,
F.
,
de Laurentiis
,
U.
,
Borghese
,
G.
,
Ambrosio
,
M.
,
Salucci
,
P.
,
Casadio
,
P.
,
Mollo
,
A.
, and
Seracchioli
,
R.
,
2023
, “
Laparoscopic Entry Techniques: Which Should You Prefer?
,”
Int. J. Gynecol. Obstet.
,
160
(
3
), pp.
742
750
.10.1002/ijgo.14412
16.
Ott
,
D. E.
,
2019
, “
Abdominal Compliance and Laparoscopy: A Review
,”
JSLS
,
23
(
1
), p.
e2018.00080
.10.4293/JSLS.2018.00080
17.
Tahan
,
N.
,
Khademi-Kalantari
,
K.
,
Mohseni-Bandpei
,
M. A.
,
Mikaili
,
S.
,
Baghban
,
A. A.
, and
Jaberzadeh
,
S.
,
2016
, “
Measurement of Superficial and Deep Abdominal Muscle Thickness: An Ultrasonography Study
,”
J. Physiol. Anthropol.
,
35
(
1
), p.
17
.10.1186/s40101-016-0106-6
18.
De Keulenaer
,
B. L.
,
De Waele
,
J. J.
,
Powell
,
B.
, and
Malbrain
,
M. L. N. G.
,
2009
, “
What Is Normal Intra-Abdominal Pressure and How Is It Affected by Positioning, Body Mass and Positive End-Expiratory Pressure?
,”
Intensive Care Med.
,
35
(
6
), pp.
969
976
.10.1007/s00134-009-1445-0
19.
Lunney
,
J.
,
2023
, “
Importance of the Pig as a Human Biomedical Model
,”
Sci. Transl. Med.
,
13
(
621
), p.
eabd5758
.10.1126/scitranslmed.abd5758
20.
Committee for the Update of the Guide for the Care and Use of Laboratory Animals, Institute for Laboratory Animal Research
,
2011
,
Guide for the Care and Use of Laboratory Animals
, 8th ed.,
National Academies Press
,
Washington, DC
.
21.
Vilos
,
G. A.
, and
Vilos
,
A. G.
,
2003
, “
Safe Laparoscopic Entry Guided by Veress Needle CO2 Insufflation Pressure
,”
J. Am. Assoc. Gynecol. Laparoscopists
,
10
(
3
), pp.
415
420
.10.1016/S1074-3804(05)60277-0
22.
Levy
,
B.
,
De Guara
,
J.
,
Willson
,
P.
,
Soon
,
Y.
,
Kent
,
A.
, and
Rockall
,
T.
,
2012
, “
Bladder Injuries in Emergency/Expedited Laparoscopic Surgery in the Absence of Previous Surgery: A Case Series
,”
Ann. R. Coll. Surg. Engl.
,
94
(
3
), pp.
e118
e120
.10.1308/003588412X13171221502149
You do not currently have access to this content.