We are presenting a novel, non-biologic model of the healthy human annulus. This lumbar Total Disc Model (TDM) ideally would be both biofidelic and sufficiently robust to withstand long-term fatigue testing without breaking down or tearing apart. Mechanical validation testing was performed to confirm that the compressive and torsional properties were similar to literature values of denucleated human lumbar discs in two-body constructs. Long-term fatigue tests were performed to establish the durability of the model. We have reported data for both our empty TDM and the TDM filled with a representative nucleus replacement device (NRD). The silicone model is geometrically equivalent to the healthy human lumbar disc, including the discoid cavity present following a total nuclectomy, the annulus fibrosis with micro-annulotomy, and the cartilaginous endplates. The pressure transmitted through the center of the disc went from negligible when the TDM was empty to over 40% when the TDM was filled. The compression stiffness was 992±15 N/mm for the empty TDM and 1583±136 N/mm for the filled TDM. The torsional stiffness was 0.505±0.024 Nm/° for the empty and 0.550±0.056 Nm/° for the filled TDM. Lastly, the only mechanical damage suffered by either empty or filled TDMs during dynamic testing came from debonding from the endplates at higher torque levels. No damage was seen during dynamic compression testing. After determining the appropriate geometry for the TDM, validation testing was performed to ensure that the load sharing, compressive, and torsional properties were similar to the native human disc. The silicone model was durable enough to avoid tearing or mechanical failure at physiologic loads. This study demonstrated that a silicone total disc model was developed with appropriate properties necessary for determining the mechanical degradation properties of a NRD and will not mechanical fail at physiologic loads.
Skip Nav Destination
e-mail: dspenciner@lifespan.org
Article navigation
March 2008
Technical Briefs
Novel Synthetic Total Disk Model for Mechanical Testing of Nucleus Replacement Devices
David Spenciner, Sc.M.,
David Spenciner, Sc.M.
P.E.
Department of Orthopaedics,
e-mail: dspenciner@lifespan.org
Brown Medical School/Rhode Island Hospital
, Providence, RI 02903
Search for other works by this author on:
Jared W. Walkenhorst,
Jared W. Walkenhorst
M.S.
SpineWave, Inc.
, Shelton, CT 06484
Search for other works by this author on:
Dennis Y. Lee,
Dennis Y. Lee
M.S.
SpineWave, Inc.
, Shelton, CT 06484
Search for other works by this author on:
David Paller
David Paller
M.S.
Department of Orthopaedics,
Brown Medical School/Rhode Island Hospital
, Providence, RI 02903
Search for other works by this author on:
David Spenciner, Sc.M.
P.E.
Department of Orthopaedics,
Brown Medical School/Rhode Island Hospital
, Providence, RI 02903e-mail: dspenciner@lifespan.org
Jared W. Walkenhorst
M.S.
SpineWave, Inc.
, Shelton, CT 06484
Dennis Y. Lee
M.S.
SpineWave, Inc.
, Shelton, CT 06484
David Paller
M.S.
Department of Orthopaedics,
Brown Medical School/Rhode Island Hospital
, Providence, RI 02903J. Med. Devices. Mar 2008, 2(1): 014502 (6 pages)
Published Online: March 18, 2008
Article history
Received:
August 22, 2007
Revised:
January 24, 2008
Published:
March 18, 2008
Citation
Spenciner, D., Walkenhorst, J. W., Lee, D. Y., and Paller, D. (March 18, 2008). "Novel Synthetic Total Disk Model for Mechanical Testing of Nucleus Replacement Devices." ASME. J. Med. Devices. March 2008; 2(1): 014502. https://doi.org/10.1115/1.2884194
Download citation file:
Get Email Alerts
Cited By
Related Articles
Determining the Fatigue Life of Dental Implants
J. Med. Devices (March,2008)
Biomechanical Evaluation of a Novel Lumbosacral Axial Fixation Device
J Biomech Eng (November,2005)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Synthetic Soft Tissue Characterization of the Mechanical Analogue Lumbar Spine
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Understanding the Problem
Design and Application of the Worm Gear
Fracture Toughness Testing Using the C-Shaped Specimen
Developments in Fracture Mechanics Test Methods Standardization