A new extended hemostasis valve for sheaths is presented, with minimized stick-slip behavior to be used in (heart) catheterization procedures during long interventions (3–6 h). The invented extension to this existing sheath bypasses the silicone rubber sealing (hemostasis valve) and replaces it with a dedicated seal with the two functions separated: (1) sealing around the catheter being used and (2) closing the sheath when the catheter is removed (valve function). Measurements have been performed on the current and the invented seals, showing that the axial friction force is reduced, with a factor of 6.4, from 1.4 N to 0.22 N.
1.
Keane
, D.
, 2002, “New Catheter Ablation Techniques for the Treatment of Cardiac Arrhythmias
,” Card. Electrophysiol. Rev.
, 6
, pp. 341
–348
. 1385-22642.
Wittkampf
, F. H. M.
, and Nakagawa
, H.
, 2006, “RF Catheter Ablation: Lessons on Lesions
,” Pacing Clin. Electrophysiol.
, 29
(11
), pp. 1285
–1297
. 0147-83893.
Ouyang
, F.
, Bansch
, D.
, Ernst
, S.
, Schaumann
, A.
, Hachiya
, H.
, Chen
, M.
, Chun
, J.
, Falk
, P.
, Khanedani
, A.
, Antz
, M.
, and Kuck
, K.
, 2004, “Complete Isolation of Left Atrium Surrounding the Pulmonary Veins: New Insights From the Double-Lasso Technique in Paroxysmal Atrial Fibrillation
,” Circulation
, 110
(15
), pp. 2090
–2096
. 0009-73224.
Haissaguerre
, M.
, Jais
, P.
, Shah
, D. C.
, Takahashi
, A.
, Hocini
, M.
, Quiniou
, G.
, Garrigue
, S.
, Le Mouroux
, A.
, Le Metayer
, P.
, and Clementy
, J.
, 1998, “Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
,” N. Engl. J. Med.
0028-4793, 339
(10
), pp. 659
–666
.5.
Seldinger
, S. I.
, 1953, “Catheter Replacement of the Needle in Percutaneous Arteriography: A New Technique
,” Acta Radiol. (1921–1962)
, 39
(5
), pp. 368
–376
. 0001-69266.
Nakagawa
, H.
, Wittkampf
, F. H. M.
, Yamanashi
, W. S.
, Pitha
, J. V.
, Imai
, S.
, Campbell
, B.
, Arruda
, M.
, Lazzara
, R.
, Jackman
, W. M.
, 1998, “Inverse Relationship Between Electrode Size and Lesion Size During Radiofrequency Ablation With Active Electrode Cooling
,” Circulation
, 98
(5
), pp. 458
–465
. 0009-73227.
Pappone
, C.
, Rosanio
, S.
, Oreto
, G.
, Tocchi
, M.
, Gugliotta
, F.
, Vicedomini
, G.
, Salvati
, A.
, Dicandia
, C.
, Mazzone
, P.
, Santinelli
, V.
, Gulletta
, S.
, Chierchia
, S.
, 2000, “Circumferential Radiofrequency Ablation of Pulmonary Vein Ostia: A New Anatomic Approach for Curing Atrial Fibrillation
,” Circulation
, 102
(21
), pp. 2619
–2628
. 0009-73228.
Pappone
, C.
, and Santinelli
, V.
, 2004, “The Who, What, Why, and How-To Guide for Circumferential Pulmonary Vein Ablation
,” J. Cardiovasc. Electrophysiol.
, 15
(10
), pp. 1226
–1230
. 1045-38739.
Guo
, X.
, and Stehr
, R.
, 2003, “Hemostasis Valve
,” US Patent No. 6551283 B1.10.
Rosielle
, P. C. J. N.
, 2007, “Constructieprincipes
,” Technical Report No. 4007 (in Dutch), Eindoven University of Technology, Eindhoven, The Netherlands.11.
van den Dobbelsteen
, J. J.
, Schooleman
, A.
, and Dankelman
, J.
, 2007, “Friction Dynamics of Trocars
,” Surg. Endosc
, 21
(8
), pp. 1338
–1343
. 0930-279412.
Lafontaine
, D. M.
, 2002, “Hemostasis Valve
,” WO Patent No. 2002-064203.Copyright © 2009
by American Society of Mechanical Engineers
You do not currently have access to this content.