It was hypothesized that the nonlinear load-displacement relationship displayed by bone could be conferred on an implant by tailoring its structure, yielding an enhanced mechanical stimulation of the tissues. Composite structures would feature piezoelectric properties that could also stimulate osteogenesis. Preliminary mechanical and electromechanical investigations of such porous structures are presented. Initial trial bowtie specimens with various aspect ratii were made from Nickel powder via a solid free form process and from stainless steel shim stocks. Poled Barium Titanate plates were sandwiched between stainless steel bowtie cells to create composite structures.Results: Under quasi-static compression, the Nickel structures displayed a nonlinear mechanical behavior at small strains and an overall strain-stress relationship similar to bone. Under cyclic compressive tests to 0.6 percent strain, all structures presented a repeatable nonlinear strain-stress behavior. The curves were fitted by a second-order polynomial whose coefficients are function of the relative density of the structure to a power n. Composite stainless steel/BaTiO3 bowtie structures confirmed that their electromechanical properties can be tailored.Discussion: Certain patients present metabolic degeneration that hamper bone healing. A ductile and tough structural material with piezoelectric properties such as the new composite structures in development presents the potential to overcome those limitations. They could have the advantages of existing devices without some of the drawbacks. Those porous implants may reduce the needs, costs, and risks linked to the additional use and implementation of an electrical stimulator and BMPs. Furthermore, the solid free form technique gives control over the mechanical properties of the structure. Thus, the mechanotransduction activity of biologic cells can be fully exploited to trigger a faster implant-tissue bonding, which could lead to reduction of surgical cost and time.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Novel re-entrant porous composite structure: a potential for orthopaedic applications
Nicolas V. Jaumard,
Nicolas V. Jaumard
University of Kansas
, Lawrence, KS USA
Search for other works by this author on:
James Smay,
James Smay
Oklahoma State University
, Stillwell, OK USA
Search for other works by this author on:
Nicolas V. Jaumard
University of Kansas
, Lawrence, KS USA
James Smay
Oklahoma State University
, Stillwell, OK USAJ. Med. Devices. Jun 2008, 2(2): 027532 (1 pages)
Published Online: June 17, 2008
Article history
Published:
June 17, 2008
Citation
Jaumard, N. V., Friis, E. A., Smay, J., and Xu, J. (June 17, 2008). "Novel re-entrant porous composite structure: a potential for orthopaedic applications." ASME. J. Med. Devices. June 2008; 2(2): 027532. https://doi.org/10.1115/1.2932757
Download citation file:
602
Views
Get Email Alerts
Cited By
Related Articles
PMMA Implants Increase Femoral Strength
J. Med. Devices (June,2008)
Human Joint Simulation Using LifeMOD Co-Simulation
J. Med. Devices (June,2008)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
Real-Time, In Vivo Measurement of Contact Pressures at a Knee Arthroplasty
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Layer Arrangement Impact on the Electromechanical Performance of a Five-Layer Multifunctional Smart Sandwich Plate
Advanced Multifunctional Lightweight Aerostructures: Design, Development, and Implementation
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Mathematical Background
Vibrations of Linear Piezostructures