Skip Nav Destination
Issues
June 2011
ISSN 1932-6181
EISSN 1932-619X
Research Papers
Modified Elliptical Machine Motor-Drive Design for Assistive Gait Rehabilitation
J. Med. Devices. June 2011, 5(2): 021001.
doi: https://doi.org/10.1115/1.4003693
Topics:
Design
,
Engines
,
Machinery
,
Motor drives
,
Motors
,
Safety
,
Kinematics
,
Pulleys
3D Graphical Rendering of Localized Lumps and Arteries for Robotic Assisted MIS
J. Med. Devices. June 2011, 5(2): 021002.
doi: https://doi.org/10.1115/1.4003736
Topics:
Algorithms
,
Biological tissues
,
Dimensions
,
Force sensors
,
Pressure
,
Robotics
,
Sensors
,
Surgery
,
Tumors
,
Rendering
Design and Preliminary Testing of a Novel Dual-Chambered Syringe
J. Med. Devices. June 2011, 5(2): 021003.
doi: https://doi.org/10.1115/1.4003822
Topics:
Biomedicine
,
Bubbles
,
Design
,
Fluids
,
Catheters
,
Surface tension
,
Mass spectrometry
Technical Briefs
A Low Power Wireless Data Acquisition Device to Monitor Gait Patterns for Children With Toe Walking During Daily Activities
Edmond H. M. Lou, Emma K. Brunton, Fraaz Kamal, Andreas Renggli, Kyle Kemp, Justin Lewicke, Dulai Sukhdeep, Joe M. Watt, John Andersen
J. Med. Devices. June 2011, 5(2): 024501.
doi: https://doi.org/10.1115/1.4003809
Design Innovation
Conceptual Design for Condylar Guiding Features of a Total Knee Replacement
J. Med. Devices. June 2011, 5(2): 025001.
doi: https://doi.org/10.1115/1.4003675
Topics:
Conceptual design
,
Design
,
Kinematics
,
Knee
,
Knee joint prostheses
,
Shapes
,
Rotation
,
Engineering prototypes
,
Physiology
,
Bearings
2011 Design of Medical Devices Conference Abstracts
Introduction
Arthur Erdman, William Durfee, Paul Iaizzo, Just Herder, John C. Bischof, Maire Johnson, Richard Bianco
J. Med. Devices. June 2011, 5(2): 027501.
doi: https://doi.org/10.1115/1.3590859
Topics:
Biomedical equipment
,
Design
,
Medical devices
,
Surgery
,
Biomedicine
Better Catheter Design With Improved Liquid Flow Through Tubes
J. Med. Devices. June 2011, 5(2): 027502.
doi: https://doi.org/10.1115/1.3587100
Topics:
Catheters
,
Design
,
Flow (Dynamics)
,
Coatings
,
Geometry
,
Biological fluid dynamics
,
Biomedical engineering
,
Hydrophobicity
,
Microorganisms
Assessment Of Antibiofilm Activity Of Magnesium Fluoride Nanoparticles-Stabilized Nanosized Emulsion After Its Coating On Biomaterial Surfaces
J. Med. Devices. June 2011, 5(2): 027502.
doi: https://doi.org/10.1115/1.3587101
Topics:
Biomaterials
,
Coating processes
,
Coatings
,
Emulsions
,
Magnesium (Metal)
,
Nanoparticles
,
Microorganisms
,
Artificial limbs
,
Biophysics
,
Magnesium compounds
A New Cemented Hip Prosthesis Concept
J. Med. Devices. June 2011, 5(2): 027503.
doi: https://doi.org/10.1115/1.3587102
A Device to Control Implant and Bone-Cement Temperatures in Cemented Arthroplasty
Antonio Completo, Marco Coutinho, Marcelo Schiller, António Ramos, Carlos Relvas, José Simões, Susana Meireles
J. Med. Devices. June 2011, 5(2): 027503.
doi: https://doi.org/10.1115/1.3589216
Topics:
Arthroplasty
,
Bone
,
Cements (Adhesives)
,
Temperature
,
Polymerization
,
Thermoelectricity
,
Artificial limbs
,
Biomaterials
,
Biomedicine
,
Control systems
Design Concept for a Total Knee Replacement with Condylar Guiding Features
J. Med. Devices. June 2011, 5(2): 027504.
doi: https://doi.org/10.1115/1.3589221
Topics:
Artificial limbs
,
Biomechanics
,
Bone
,
Design
,
Kinematics
,
Knee joint prostheses
,
Orthotics
,
Prostheses
Hemodynamic Changes Induced by Pneumoperitoneum and Measured With ECOM
Timothy Shine, David Corda, Stephen Aniskevich, Bruce Leone, Neil Feinglass, Sorin Brull, Booyeon Han
J. Med. Devices. June 2011, 5(2): 027504.
doi: https://doi.org/10.1115/1.3589225
Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
J. Med. Devices. June 2011, 5(2): 027505.
doi: https://doi.org/10.1115/1.3589227
Control of a Powered Lower Limb Prosthetic Device
J. Med. Devices. June 2011, 5(2): 027505.
doi: https://doi.org/10.1115/1.3589229
Topics:
Artificial limbs
,
Prostheses
,
Position control
,
Biomedicine
,
Control systems
,
Torque control
On Modeling Assumptions in FEA of Stents
J. Med. Devices. June 2011, 5(2): 027506.
doi: https://doi.org/10.1115/1.3589230
Cerebrospinal Fluid Volume Monitoring for Hydrocephalus Therapy
J. Med. Devices. June 2011, 5(2): 027506.
doi: https://doi.org/10.1115/1.3589231
Material Handling System for Robotic Natural Orifice Surgery
J. Med. Devices. June 2011, 5(2): 027507.
doi: https://doi.org/10.1115/1.3589286
Topics:
Materials handling
,
Robotics
,
Surgery
,
Endoscopes
,
Biomedicine
,
Materials handling equipment
,
Orifices
A 2D Model With Fluid-Structure Interactions for Coarctated Arteries
J. Med. Devices. June 2011, 5(2): 027507.
doi: https://doi.org/10.1115/1.3589287
Design and Testing of a Three Fingered Flexural Laparoscopic Grasper
J. Med. Devices. June 2011, 5(2): 027508.
doi: https://doi.org/10.1115/1.3589289
Topics:
Biomedicine
,
Design
,
Robotics
,
Surgery
,
Testing
An Ontology Model for the Medical Device Product Development Process and Environment
J. Med. Devices. June 2011, 5(2): 027508.
doi: https://doi.org/10.1115/1.3589290
New Process and Device for Minimal Invasive Surgical Suturing
J. Med. Devices. June 2011, 5(2): 027509.
doi: https://doi.org/10.1115/1.3589811
Topics:
Surgery
,
Biological tissues
,
Laser welding
,
Biomedical equipment
,
Biomedicine
,
Lasers
SOMNUS: A Sleep-Measuring Shirt Based on Chest Expansion and Respiratory Patterns
J. Med. Devices. June 2011, 5(2): 027509.
doi: https://doi.org/10.1115/1.3589813
Topics:
Sleep
,
Sensors
,
Medical disorders
,
Medical signal processing
,
Patient diagnosis
,
Pneumatics
Nasogastric Tube Design to Reduce Clogging and Simplify Flushing
James A. Ankrum, Alison Olechowski, Jose A. Canseco, Elliot Greenblatt, Michael P. Roberts, Nevan C. Hanumara, Alexander H. Slocum
J. Med. Devices. June 2011, 5(2): 027510.
doi: https://doi.org/10.1115/1.3589815
Topics:
Biomedical equipment
,
Design
,
Pipe flow
,
Surgery
Concept Selection in the Development of Medical Devices: The Case of the Smart Stent-Graft
J. Med. Devices. June 2011, 5(2): 027510.
doi: https://doi.org/10.1115/1.3589826
Topics:
Medical devices
,
Stents
,
Biomedical equipment
Design of a Pressure-Sensing Laparoscopic Grasper
J. Med. Devices. June 2011, 5(2): 027511.
doi: https://doi.org/10.1115/1.3589827
Topics:
Biomedical equipment
,
Design
,
Ergonomics
,
Pressure
,
Pressure sensors
,
Surgery
A Hydraulically Controlled Nonoperative Magnetic Treatment for Long Gap Esophageal Atresia
Austin Oehlerking, James D. Meredith, Ian C. Smith, Phillip M. Nadeau, Teresa Gomez, Zachary A. Trimble, David P. Mooney, David L. Trumper
J. Med. Devices. June 2011, 5(2): 027511.
doi: https://doi.org/10.1115/1.3589828
Evaluation of a Novel Method of Shunting for Patients With Normal Pressure Hydrocephalus
J. Med. Devices. June 2011, 5(2): 027512.
doi: https://doi.org/10.1115/1.3589829
Topics:
Artificial limbs
,
Biological fluid dynamics
,
Biomedical equipment
,
Biomedicine
,
Brain
,
Control systems
,
Medical disorders
,
Pressure
,
Prostheses
,
Pumps
Design and Development of an Improved Tissue Retractor for Use in Minimally Invasive Surgical Procedures
J. Med. Devices. June 2011, 5(2): 027512.
doi: https://doi.org/10.1115/1.3589830
Topics:
Biological tissues
,
Design
,
Surgery
,
Biomedical equipment
Can Hypodermic Needle Injections Be Successfully Simulated and Analyzed in the Laboratory?
J. Med. Devices. June 2011, 5(2): 027513.
doi: https://doi.org/10.1115/1.3589832
Topics:
Lubricants
,
Needles
,
Skin
,
Biomedical equipment
,
Biomedical ultrasonics
,
Patient treatment
Autologous Transfusion Device for Use in Resource-Limited Settings
J. Med. Devices. June 2011, 5(2): 027513.
doi: https://doi.org/10.1115/1.3589835
Topics:
Biomedical equipment
,
Blood
,
Obstetrics
,
Patient treatment
Improvements to the Design of a Compact Robot for Minimally Invasive Surgery
J. Med. Devices. June 2011, 5(2): 027514.
doi: https://doi.org/10.1115/1.3589902
Topics:
Design
,
Robots
,
Surgery
,
Gears
,
Reliability
,
Robotics
,
Biomedicine
Development of an ISO 13485 AND FDA QSR Compliant Quality System for an Academic R&D Group: From Concept to Certification
J. Med. Devices. June 2011, 5(2): 027514.
doi: https://doi.org/10.1115/1.3589903
The Effect of Stakeholder Data on a Fuzzy Based Modular System for Medical Device Design and Development
J. Med. Devices. June 2011, 5(2): 027515.
doi: https://doi.org/10.1115/1.3589904
Topics:
Biochemistry
,
Biomedical equipment
,
Biomedical measurement
,
Blood
,
Design
,
Medical devices
An Automated Method for Creation of Patient-Specific Volumetric Articular Cartilage Elements in the Human Foot
J. Med. Devices. June 2011, 5(2): 027515.
doi: https://doi.org/10.1115/1.3589905
Topics:
Biomedicine
,
Bone
,
Cartilage
,
Physiology
Effect of Component Misalignment on Human Tissue Temperatures Associated With Recharging Neuromodulation Devices
J. Med. Devices. June 2011, 5(2): 027516.
doi: https://doi.org/10.1115/1.3589907
Topics:
Biological tissues
,
Temperature
,
Artificial limbs
,
Biomedical equipment
,
Neurophysiology
,
Prostheses
Early Stage Economic Evaluation with a Small Medical Device Start-Up Company Using a Markov Model
J. Med. Devices. June 2011, 5(2): 027516.
doi: https://doi.org/10.1115/1.3590366
Topics:
Biomedical equipment
,
Diseases
,
Economic analysis
,
Economics
,
Innovation
,
Markov processes
,
Medical devices
,
Patient treatment
Adult Male Circumcision Device for Use in Clinical Settings
Paul F. McAlpine, Lai Yu Leo Tse, Anupinder S. Dulat, Christopher S. McAlpine, Amir Sabet Sarvestani, Kathleen H. Sienko
J. Med. Devices. June 2011, 5(2): 027517.
doi: https://doi.org/10.1115/1.3590368
Topics:
Biomedical equipment
,
Diseases
Determination of Surgical Robot Tool Force Requirements Through Tissue Manipulation and Suture Force Measurement
J. Med. Devices. June 2011, 5(2): 027517.
doi: https://doi.org/10.1115/1.3590369
Topics:
Biological tissues
,
Force measurement
,
Robots
,
Surgery
,
Robotics
,
Biomedicine
,
Manipulators
Multifunctional Articulating Surgical Robot for NOTES
Wei Jian Chin, Akiko Nakamura, Michael Head, Shane Farritor, Dmitry Olyenikov, Carl A. Nelson, Chi Min Seow
J. Med. Devices. June 2011, 5(2): 027518.
doi: https://doi.org/10.1115/1.3590375
Topics:
Robots
,
Surgery
,
Robotics
,
End effectors
,
Biomedicine
,
Endoscopes
Design of a Mobile Head Support Based on a Compliant Mechanism
J. Med. Devices. June 2011, 5(2): 027518.
doi: https://doi.org/10.1115/1.3590377
Topics:
Biomedical equipment
,
Compliant mechanisms
,
Design
,
Diseases
,
Muscle
Low-Intensity Ultrasound Alleviates Osteoarthritis In Vitro and in a Rabbit Model
J. Med. Devices. June 2011, 5(2): 027519.
doi: https://doi.org/10.1115/1.3590371
Topics:
Biomedical ultrasonics
,
Biophysics
,
Enzymes
,
Medical disorders
,
Molecular biophysics
,
Osteoarthritis
,
Radiation therapy
,
Surgery
,
Ultrasound
Prosthetic Ankle-Foot System That Adapts to Sloped Surfaces
J. Med. Devices. June 2011, 5(2): 027519.
doi: https://doi.org/10.1115/1.3590378
Topics:
Artificial limbs
,
Prostheses
,
Wear
,
Biomechanics
Development of an Endocardial Cryoablation Catheter for Concomitant Delivery of Cryogenic Treatment and Adjuvants
J. Med. Devices. June 2011, 5(2): 027520.
doi: https://doi.org/10.1115/1.3590386
Sensorless Haptic Feedback in a Surgical Robot for Telesurgery
J. Med. Devices. June 2011, 5(2): 027520.
doi: https://doi.org/10.1115/1.3590387
Topics:
Feedback
,
Haptics
,
Robots
,
Surgery
,
Robotics
,
Biomedicine
,
Force feedback
,
Force measurement
,
Manipulators
,
Telemedicine
Deployment of Interwoven Stents in an Artery With Moderate Stenosis
J. Med. Devices. June 2011, 5(2): 027521.
doi: https://doi.org/10.1115/1.3590552
Topics:
Stents
,
Finite element analysis
,
Biomaterials
,
Biomechanics
,
Blood vessels
A Pulsatile-Flow Model for Intracardiac Surgical Device Development
J. Med. Devices. June 2011, 5(2): 027521.
doi: https://doi.org/10.1115/1.3590584
Topics:
Pulsatile flow
,
Surgery
,
Catheters
,
Bellows (Equipment)
,
Diseases
,
Hemodynamics
,
Physiology
Patterning PLA Packaging Films for Implantable Medical Devices
J. Med. Devices. June 2011, 5(2): 027522.
doi: https://doi.org/10.1115/1.3590627
Topics:
Medical devices
,
Packaging
,
Embossing
,
Etching
,
Biomaterials
,
Cochlear implants
,
Polymer films
Optical System Design of Laser-Based Stethoscope
J. Med. Devices. June 2011, 5(2): 027522.
doi: https://doi.org/10.1115/1.3590692
Design of a Motion Compensated Tissue Resection Catheter for Beating Heart Cardiac Surgery
J. Med. Devices. June 2011, 5(2): 027523.
doi: https://doi.org/10.1115/1.3590649
Topics:
Biological tissues
,
Catheters
,
Design
,
Surgery
,
Biomedical ultrasonics
,
Cardiovascular system
Learning the Art of Disciplined Innovation
J. Med. Devices. June 2011, 5(2): 027523.
doi: https://doi.org/10.1115/1.3590703
Topics:
Biomedical engineering
,
Biomedicine
,
Data mining
,
Innovation
Single Entry Tunneler (SET) for Hemodialysis Graft Procedures
Madalyn S. Berns, Elizabeth Tsai, Jesse Austin-Breneman, James C. Schulmeister, Edward Sung, Charles Keith Ozaki, Conor J. Walsh
J. Med. Devices. June 2011, 5(2): 027524.
doi: https://doi.org/10.1115/1.3590704
Topics:
Biological tissues
,
Biomaterials
,
Biomedical equipment
,
Biomedicine
,
Hemodialysis
,
Imaging
,
Nickel alloys
,
Optical cables
,
Patient treatment
,
Stainless steel
Design of an Osseointegrated Lower Limb Prosthetic Force Limiting Connection
J. Med. Devices. June 2011, 5(2): 027524.
doi: https://doi.org/10.1115/1.3590705
Topics:
Artificial limbs
,
Design
,
Bone
,
Torsion
,
Biomechanics
Diffuse Near Infrared Wound Monitor for Quantifying Chronic Wound Healing
J. Med. Devices. June 2011, 5(2): 027525.
doi: https://doi.org/10.1115/1.3590706
Topics:
Biomedicine
,
Imaging
,
Infrared spectroscopy
,
Patient monitoring
,
Proteins
,
Wounds
Modeling of Chicken Meat Blade Cutting Using Finite Element Method
J. Med. Devices. June 2011, 5(2): 027525.
doi: https://doi.org/10.1115/1.3590708
Topics:
Blades
,
Cutting
,
Finite element methods
,
Modeling
,
Fracture (Materials)
,
Fracture (Process)
,
Bone
,
Biomechanics
,
Finite element analysis
,
Food engineering
Dual-Direction Optical Measurement Instrument for Assisting X-Ray Mammography
J. Med. Devices. June 2011, 5(2): 027526.
doi: https://doi.org/10.1115/1.3590858
Topics:
Instrumentation
,
Mammography
,
Optical measurement
,
X-rays
,
Image reconstruction
,
Imaging
,
Tumors
,
Biomedicine
,
Cancer
,
Diagnostic radiography
Design and Implementation of Noncontact Measurement Device for Irregular Dental Osseointegration Detection
J. Med. Devices. June 2011, 5(2): 027526.
doi: https://doi.org/10.1115/1.3590860
Topics:
Artificial limbs
,
Biomedical measurement
,
Biomedicine
,
Bone
,
Design
,
Prostheses
,
Transducers
Design of an Instrument Guide for MRI-Guided Percutaneous Interventions
J. Med. Devices. June 2011, 5(2): 027527.
doi: https://doi.org/10.1115/1.3590861
Topics:
Design
,
Instrumentation
,
Magnetic resonance imaging
,
Skin
,
Biomedical equipment
,
Biomedicine
Simultaneous In Vivo Assessment of Contractile Properties and Electromyographic (EMG) Activities in a Knock-Out Mouse Model of Myotonic Dystrophy
J. Med. Devices. June 2011, 5(2): 027527.
doi: https://doi.org/10.1115/1.3590863
The Randomized Withdrawal Study Design: A Flexible Study Design for use in Regulated Medical Device Studies
J. Med. Devices. June 2011, 5(2): 027528.
doi: https://doi.org/10.1115/1.3590864
Topics:
Experimental design
,
Medical devices
,
Drugs
,
Biomedical equipment
Intelligent Motor Powered Prosthetic Knee Joint
J. Med. Devices. June 2011, 5(2): 027528.
doi: https://doi.org/10.1115/1.3590866
Topics:
Artificial limbs
,
Engines
,
Knee
,
Motors
,
Muscle
,
Prostheses
,
Springs
,
Gait analysis
A Comparitive Overview of Existing and Experimental Morcellators in Gynecology and Urology
J. Med. Devices. June 2011, 5(2): 027529.
doi: https://doi.org/10.1115/1.3590867
Topics:
Gynecology
,
Biological tissues
,
Endoscopes
,
Surgery
Proposed Protocol for Objective Morcellator Analysis
J. Med. Devices. June 2011, 5(2): 027529.
doi: https://doi.org/10.1115/1.3590868
Topics:
Biomedical equipment
,
Surgery
Small-Scale Hydraulics for Human Assist Devices
J. Med. Devices. June 2011, 5(2): 027530.
doi: https://doi.org/10.1115/1.3590872
Topics:
Artificial limbs
,
Fluid mechanics
,
Hydraulic actuators
,
Hydraulic drive systems
,
Hydraulics
,
Orthotics
,
Prostheses
Multimodal Automated Quantitative Sensory Testing System for Pain Research
Grant Kruger, Steve E. Harte, Eric Ichesco, Mainak Mitra, Shen Keat Cheok, Xu Yun, Daniel J. Clauw, Albert Shih
J. Med. Devices. June 2011, 5(2): 027530.
doi: https://doi.org/10.1115/1.3590873
Topics:
Biological tissues
,
Biomedicine
,
Diseases
,
Health care
,
Noise (Sound)
,
Patient treatment
,
Testing
Automated 3D Mosaicing and Scan Trajectories for Surveillance of Bladder Cancer
J. Med. Devices. June 2011, 5(2): 027531.
doi: https://doi.org/10.1115/1.3590874
Topics:
Cancer
,
Surveillance
,
Endoscopes
,
Mechatronics
,
Biomedicine
,
Image reconstruction
,
Image segmentation
,
Imaging
,
Medical image processing
,
Robotics
Multifunction Pericardial Drainage Catheter
J. Med. Devices. June 2011, 5(2): 027531.
doi: https://doi.org/10.1115/1.3590875
Topics:
Catheters
,
Drainage
,
Surgery
,
Drug delivery systems
,
Cardiology
A Method and Apparatus to Simulate Physiologic Right Side Heart Movement in a Fresh Human Cadaver: Pilot Studies
J. Med. Devices. June 2011, 5(2): 027532.
doi: https://doi.org/10.1115/1.3590876
Topics:
Biomechanics
,
Cardiovascular system
,
Catheters
,
Hemodynamics
,
Hemorheology
,
Physiology
Development of a Database for Global Health Medical Devices
Amir Sabet Sarvestani, Joseph Perosky, Kelley Maynard, Michael Weist, Chang Jiang, Kathleen H. Sienko
J. Med. Devices. June 2011, 5(2): 027532.
doi: https://doi.org/10.1115/1.3590877
Task-Specific Multiple-Arm Minimally Invasive Surgical Device Design Using Cooperative Kinematic Isotropy Indices
J. Med. Devices. June 2011, 5(2): 027533.
doi: https://doi.org/10.1115/1.3590878
Topics:
Design
,
Isotropy
,
Kinematics
,
Surgery
,
Manipulators
,
Redundancy (Engineering)
,
Robotics
,
Biomedicine
,
Design engineering
,
Robot kinematics
Kinematic and Workspace Comparison of Four and Five Degree of Freedom Miniature In Vivo Surgical Robot
Ryan McCormick, Tyler D. Wortman, Kyle W. Strabala, Tom P. Frederick, Dmitry Oleynikov, Shane M. Farritor
J. Med. Devices. June 2011, 5(2): 027533.
doi: https://doi.org/10.1115/1.3590880
Topics:
Degrees of freedom
,
Kinematics
,
Robots
,
Surgery
,
User interfaces
,
Biomedicine
,
Endoscopes
,
Robotics
Synthesis of Silica-Coated Iron Oxide Nanoparticles for Magnetic Resonance Contrast Enhancement and Thermal Therapies
J. Med. Devices. June 2011, 5(2): 027534.
doi: https://doi.org/10.1115/1.3591376
Variations in Human Cardiac Vein Anatomies: Direct Mapping Within Fixed Hearts and Digital Reconstructions
J. Med. Devices. June 2011, 5(2): 027534.
doi: https://doi.org/10.1115/1.3591377
Development of an Automatically Adjustable Colonoscope
J. Med. Devices. June 2011, 5(2): 027535.
doi: https://doi.org/10.1115/1.3591379
Topics:
Actuators
,
Biomedicine
,
Endoscopes
,
Imaging
,
Manipulators
,
Position control
,
Robotics
Localization of the Distal Tip in the Colonoscopy Training Model Using Light Sensors
J. Med. Devices. June 2011, 5(2): 027535.
doi: https://doi.org/10.1115/1.3591380
Topics:
Biomedicine
,
Cancer
,
Data acquisition
,
Education
,
Endoscopes
,
Imaging
,
Sensors
A Design Framework of Unloaded Leaflet Shape for the Ovine Pulmonary Valve Single Leaflet Replacement Surgery
J. Med. Devices. June 2011, 5(2): 027536.
doi: https://doi.org/10.1115/1.3591385
Topics:
Design
,
Shapes
,
Surgery
,
Valves
,
Deformation
,
Finite element analysis
,
Pediatrics
,
Artificial limbs
,
Biomaterials
,
Biomechanics
Innovative Renal Cooling Device for Use in Minimally Invasive Surgery
J. Med. Devices. June 2011, 5(2): 027536.
doi: https://doi.org/10.1115/1.3591386
Topics:
Cooling
,
Kidney
,
Surgery
,
Cancer
,
Biomedical equipment
,
Medical disorders
An Approach to Seizure Onset Detection Using Fuzzy Logic Based on Seizure Evolution in Intracranial EEG
J. Med. Devices. June 2011, 5(2): 027537.
doi: https://doi.org/10.1115/1.3591388
Esophageal Prosthesis For Refractory Gastresophageal Reflux Disease Prevention
J. Med. Devices. June 2011, 5(2): 027537.
doi: https://doi.org/10.1115/1.3591390
Topics:
Diseases
,
Prostheses
,
Silicones
,
Biomaterials
,
Compressibility
,
Deformation
,
Nickel alloys
,
Surgery
,
Titanium alloys
Feasibility Study of MEMs Technique for Characterizing Magnetic Susceptibility of Subcellular Organelles
J. Med. Devices. June 2011, 5(2): 027538.
doi: https://doi.org/10.1115/1.3591391
Design of an Autoclavable Active Cannula Deployment Device
Trevor Bruns, John Tucker, D. Caleb Rucker, Philip Swaney, Emad Boctor, E. Clif Burdette, Jessica Burgner, Robert Webster
J. Med. Devices. June 2011, 5(2): 027538.
doi: https://doi.org/10.1115/1.3591392
Topics:
Artificial limbs
,
Catheters
,
Design
,
Prostheses
,
Surgery
Methods to Prepare Perfusion Fixed Cardiac Specimens for Multimodal Imaging: The Use of Formalin and Agar Gels
J. Med. Devices. June 2011, 5(2): 027539.
doi: https://doi.org/10.1115/1.3591396
Design of a Novel Experimental Setup for the Assessment of the Fossa Ovalis Within Large Mammalian Hearts: Investigating Tissue Properties and Clinical Devices Used for Transseptal Access
J. Med. Devices. June 2011, 5(2): 027539.
doi: https://doi.org/10.1115/1.3591402
Topics:
Biological tissues
,
Biomaterials
,
Biomechanics
,
Blood vessels
,
Cardiovascular system
,
Catheters
,
Design
,
Surgery
Determining the Region Accuracy of a Region-Based P300 Speller Paradigm
J. Med. Devices. June 2011, 5(2): 027540.
doi: https://doi.org/10.1115/1.3591405
Infrascanner: Cost Effective, Mobile Medical Imaging System for Detecting Hemotomas
J. Med. Devices. June 2011, 5(2): 027540.
doi: https://doi.org/10.1115/1.3591407
Topics:
Biomedical imaging
,
Biomedicine
,
Blood
,
Brain
,
Cancer
,
Imaging
,
Infrared imaging
,
Neurophysiology
,
Optical scanners
,
Wounds
Minimally Invasive Iliac Crest Bone Graft Harvesting: A Design and Business Method Overview
Maxim Budyansky, Neil Shah, Haim Gottfried, Peter Truskey, Shoval Dekel, A. Jay Khanna, Khaled Kebaish, Lee Riley Johns
J. Med. Devices. June 2011, 5(2): 027541.
doi: https://doi.org/10.1115/1.3591412
Topics:
Bone
,
Design
,
Surgery
,
Tissue engineering
Improving the Performance of Implantable Electrostimulation Devices Using Electrically Conducting Polymers
J. Med. Devices. June 2011, 5(2): 027541.
doi: https://doi.org/10.1115/1.3591415
Topics:
Conducting polymers
,
Electrodes
,
Artificial limbs
,
Biomedicine
,
Prostheses
,
Bioelectric phenomena
,
Biomaterials
,
Cardiology
,
Neurophysiology