Abstract

In this study, the influence of the orientation of embedded piezoelectric ceramic lead zirconium titanate (PZT) on the mechanical performance of hybrid fiber-reinforced (polypropylene and glass fiber) concrete beams was evaluated. The performance of concrete was evaluated under self-weight, followed by assessing the mechanical property using the electromechanical impedance (EMI) technique after optimization of M30 grade concrete with polypropylene fiber and glass fiber. PZT patches are embedded at different orientations, i.e., 0 deg, 45 deg, and 90 deg, with the axis of the structure for monitoring the hydration of the RC beam. The change in stiffness due to heat hydration in the concrete structure after 5, 7, 14, 21, and 28 days was observed by curing hybrid concrete beams and examining them after 5, 7, 14, 21, and 28 days. On the fifth day, beams were simply supported and allowed to deflect under their weight, and measurements of heat hydration in terms of conductance at frequencies ranging between 1 and 1000 kHz were done. Similarly, days 7, 14, 21, and 28 were done. Day 5 was considered the baseline. It is noted that the PZT sensor placed at an angle of 45 deg is the least effective in recording the incremental changes in hydration that occurred in the concrete beam. The highest quality results were obtained at 90 deg, which is further demonstrated by statistically quantifying the changes using the root-mean-square deviation (RMSD) percentage method and proves to be the most optimized orientation to obtain the stiffness of the hybrid reinforced beam in terms of conductance.

References

1.
Aarthi
,
K.
, and
Arunachalam
,
K.
,
2018
, “
Durability Studies on Fiber Reinforced Self Compacting Concrete With Sustainable Wastes
,”
J. Cleaner Prod.
,
174
, pp.
247
255
.
2.
Abdul-Rahman
,
M.
,
Al-Attar
,
A. A.
,
Hamada
,
H. M.
, and
Tayeh
,
B.
,
2020
, “
Microstructure and Structural Analysis of Polypropylene Fiber Reinforced Reactive Powder Concrete Beams Exposed to Elevated Temperature
,”
J. Build. Eng.
,
29
, p
101167
.
3.
Bankir
,
M. B.
, and
Korkut Sevim
,
U.
,
2020
, “
Performance Optimization of Hybrid Fiber Concretes Against Acid and Sulfate Attack
,”
J. Build. Eng.
,
32
, p.
101443
.
4.
Chasioti
,
S. G.
, and
Vecchio
,
F. J.
,
2017
, “
Shear Behavior and Crack Control Characteristics of Hybrid Steel Fiber-Reinforced Concrete Panels
,”
ACI Struct. J.
,
114
(
1
), pp.
209
220
.
5.
Gu
,
L.
,
Visintin
,
P.
, and
Bennett
,
T.
,
2018
, “
Evaluation of Accelerated Degradation Test Methods for Cementitious Composites Subject to Sulfuric Acid Attack; Application to Conventional and Alkali-Activated Concretes
,”
Cem. Concr. Compos.
,
87
, pp.
187
204
.
6.
Kiruthika
,
A. V.
,
2017
, “
A Review on Physico-Mechanical Properties of Bast Fiber Reinforced Polymer Composites
,”
J. Build. Eng.
,
9
, pp.
91
99
.
7.
Kushartomo
,
W.
, and
Ivan
,
R.
,
2017
, “
Effect of Glass Fiber on Compressive, Flexural and Spliting Strength of Reactive Powder Concrete
,”
MATEC Web Conf.
,
138
, p.
03010
.
8.
Lakshmi
,
A.
,
Pandit
,
P.
,
Bhagwat
,
Y.
, and
Nayak
,
G.
,
2022
, “
A Review on Efficiency of Polypropylene Fiber-Reinforced Concrete
,”
Lect. Notes Civ. Eng.
,
162
, pp.
799
812
.
9.
Megahed
,
M.
,
Abo-bakr
,
R. M.
, and
Mohamed
,
S. A.
,
2020
, “
Optimization of Hybrid Natural Laminated Composite Beams for a Minimum Weight and Cost Design
,”
Compos. Struct.
,
239
, p.
111984
.
10.
2008
, “Natural Fibers and Their Composites,”
Tribology of Natural Fiber Polymer Composites
, pp.
1
58
.
11.
Divsholi, B.S., Yang, Y., and Bing, L., 2009, “Monitoring Beam-Column Joint in Concrete Structures Using Piezo-lmpedance Sensors,” Adv. Mater. Res., 79–82, pp.
59
62
.
12.
Wang
,
D.
, and
Zhu
,
H.
,
2011
, “
Monitoring of the Strength Gain of Concrete Using Embedded PZT Impedance Transducer
,”
Constr. Build. Mater.
,
25
(
9
), pp.
3703
3708
.
You do not currently have access to this content.