Abstract

This paper presents the results of neutron detection efficiency and dosimetry between a borated centrifugally tensioned metastable fluid detector (B-CTMFD) configured to detect thermal to fast neutrons versus two widely used neutron detection devices of similar form factors: moderated He-3 based Ludlum-42-49B neutron detector, and, the Fuji Electric's NSN3TM (NNSN3) pressurized nitrogen-methane filled neutron detector. The one-on-one performance comparisons were conducted using soft (Cf-252 fission) neutron spectrum isotope neutron sources positioned behind various levels of lead and concrete shielding ranging in thickness from 0 cm (unshielded) to up to 30 cm. The comparisons were conducted with Monte Carlo N-Particle transport code (MCNP) code simulations to account for three-dimensional effects and to relate the absolute detection rate with the dose rate—to derive the sensitivity factor (cpm/μSv/h). While the Ludlum 42-49B and NSN3 detectors operate at a fixed sensitivity setting, the centrifugally tensioned metastable fluid detector (CTMFD) can be (and was) operated to detect and separate the contributions from epithermal (0.02 eV–0.2 MeV) and from fast (>0.2 MeV) neutrons at various sensitivity levels by varying the tensioned metastable negative pressure (Pneg) from 0.3 MPa to 0.7 MPa. The B-CTMFD (configured for detecting the full 0.02 eV to 12 MeV neutrons >0.1 MeV neutron detection at Pneg = 0.7 MPa) offered relative sensitivity enhancements of up to ∼22× greater than Ludlum and over 5× greater than NSN3, over the 0-15 cm range of Pb shielding, and the 0–30 cm concrete shield thickness. The contribution from detecting down scattered neutrons increases with increased thickness, especially for concrete shielding. The B-CTMFD design overcomes the detection penalty (up to 60% depending on shielding type and thickness) inherent in the nonborated centrifugally tensioned metastable fluid detector (NB-CTMFD), designed only to detect fast-energy neutrons—as described in the companion (Part-1) paper. However, unlike the NB-CTMFD, which used 100% decafluorapentane (DFP) (C5H2F10), the B-CTMFD requires the use of an azeotropic mixture of DFP, methanol, and tri-methyl borate (TMB—C3H9BO3, using natural boron) in 80:4:16 proportion. The B-CTMFD was about 6 times more sensitive than NB-CTMFD under the most heavily shielded condition and, taken together, also offered 2-energy bin neutron spectroscopic enablement, together with 22-5× higher absolute efficiency and relative sensitivity compared with the nonspectroscopic Ludlum (He-3) and NSN3 (methane-nitrogen) based detectors. From an intrinsic efficiency standpoint, the B-CTMFD operating at Pneg = 0.7 MPa state demonstrated ∼103× higher intrinsic efficiency over Ludlum 42-49B and NSN3 detectors, respectively.

References

1.
Archambault
,
B.
,
Hagen
,
A.
,
Masuda
,
K.
,
Yamakawa
,
N.
, and
Taleyarkhan
,
R. P.
,
2017
, “
Threshold Rejection Mode Active Interrogation of SNMs Using Continuous Beam DD Neutrons With Centrifugal and Acoustic Tensioned Metastable Fluid Detectors
,”
IEEE Trans. Nucl. Sci.
,
64
(
7
), pp.
1781
1788
.10.1109/TNS.2016.2628244
2.
Ota
,
Y.
,
Ozerov
,
S.
, and
Taleyarkhan
,
R. P.
,
2024
, “
Performance of CTMFD Detector versus Ludlum 42-49B, Fuji NSN3 Detectors for Hard (Am-Be) and Soft (Cf-252 Fission) Neutron Energy Spectra for Sources Within Lead/Concrete Shielded Configurations
,”
ASME J. Nucl. Eng. Radiat.
, epub.10.1115/1.4065852
3.
Taleyarkhan
,
R. P.
,
Lapinskas
,
J.
, and
Xu
,
Y.
,
2008
, “
Tensioned Metastable Fluids and Nanoscale Interactions With External Stimuli—Theoretical-Cum-Experimental Assessments and Nuclear Engineering Applications
,”
Nucl. Eng. Des.
,
238
(
7
), pp.
1820
1827
.10.1016/j.nucengdes.2007.10.019
4.
Taleyarkhan
,
R. P.
,
2020
, “
Monitoring Neutron Radiation in Extreme Gamma/X-Ray Radiation Fields
,”
Sensors
,
20
(
3
), p.
640
.10.3390/s20030640
5.
Hagen
,
A.
,
2018
, “
Detection and Interdiction of Shielded and Unshielded Special Nuclear Material Using Tensioned Metastable Fluid Detectors
,” Ph.D. dissertation,
Purdue University
,
West Lafayette, IN
.
6.
Taleyarkhan
,
R. P.
,
Archambault
,
B.
,
Sansone
,
A.
,
Grimes
,
T. F.
, and
Hagen
,
A.
,
2020
, “
Neutron Spectroscopy & H*10 Dosimetry With Tensioned Metastable Fluid Detectors
,”
Nucl. Instrum. Methods Phys. Res., Sect. A
,
959
, p.
163278
.10.1016/j.nima.2019.163278
7.
Ludlum Measurement, Inc.
,
2024
, “
LUDLUM MODEL 42-49 & 42-49B Neutron Detector
,”
Ludlum Measurement, Inc.
,
Sweetwater, TX
, accessed July 4, 2024, https://ludlums.com/
8.
Nunomiya
,
T.
,
Nakamura
,
T.
,
Yamamura
,
S.
, and
Amano
,
T.
,
2017
, “
Development of Lightweight Portable Neutron Survey Meter
,”
J. Nucl. Sci. Technol.
,
54
(
11
), pp.
1215
1222
.10.1080/00223131.2017.1359115
9.
Sansone
,
A.
,
2021
, “
Neutron Spectroscopy Development in Tensioned Metastable Fluid Detectors
,”
Ph.D. dissertation
,
Purdue University
,
West Lafayette, IN
.https://hammer.purdue.edu/articles/thesis/Neutron_Spectroscopy_Development_in_Tensioned_Metastable_Fluid_Detectors/14522682
10.
Brown
,
D. A.
,
Chadwick
,
M. B.
,
Capote
,
R.
,
Kahler
,
A. C.
,
Trkov
,
A.
,
Herman
,
M. W.
,
Sonzogni
,
A. A.
, et al.,
2018
, “
ENDF/B-VIII.0: The 8th Major Release of the Nuclear Reaction Data Library With CIELO-Project Cross Sections, New Standards and Thermal Scattering Data
,”
Nucl. Data Sheets
,
148
, pp.
1
142
.10.1016/j.nds.2018.02.001
11.
ICRP (International Committee on Radiological Protection)
,
1997
, “
Conversion Coefficients for Use in Radiological Protection Against External Radiation
,”
Pergamon Press
, New York,
Report No. 74
.https://www.icrp.org/publication.asp?id=ICRP%20Publication%2074
You do not currently have access to this content.